LDPE板材水树劣化试验下耗散电流波形监测

T. Osada, K. Tohyama, T. Imai, K. Abe
{"title":"LDPE板材水树劣化试验下耗散电流波形监测","authors":"T. Osada, K. Tohyama, T. Imai, K. Abe","doi":"10.1109/CEIDP.2008.4772817","DOIUrl":null,"url":null,"abstract":"The dissipation current waveform observation method is considered one of possible way as a diagnostic method for the un-bridged water tree on the high-voltage class power cable. In this paper, in order to clarify the time variations with the un-bridged water tree growth, by using the special chamber and setup, the dissipation current waveforms monitoring under the high voltage application test of LDPE sheet with soaking the sample into the saline solution was carried out at the applied frequency 1 kHz and applied voltage 2 kVrms for 300 hours. As the results of the high voltage application test, it was confirmed that the electric field dependence of the phase of 3rd harmonic of dissipation current strongly related with the deterioration rate of un-bridged water tree.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Dissipation Current Waveforms Monitoring under Water Tree Deterioration Test of LDPE Sheet\",\"authors\":\"T. Osada, K. Tohyama, T. Imai, K. Abe\",\"doi\":\"10.1109/CEIDP.2008.4772817\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The dissipation current waveform observation method is considered one of possible way as a diagnostic method for the un-bridged water tree on the high-voltage class power cable. In this paper, in order to clarify the time variations with the un-bridged water tree growth, by using the special chamber and setup, the dissipation current waveforms monitoring under the high voltage application test of LDPE sheet with soaking the sample into the saline solution was carried out at the applied frequency 1 kHz and applied voltage 2 kVrms for 300 hours. As the results of the high voltage application test, it was confirmed that the electric field dependence of the phase of 3rd harmonic of dissipation current strongly related with the deterioration rate of un-bridged water tree.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772817\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772817","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

将耗散电流波形观测方法作为高压类电力电缆非桥接水树的一种可能的诊断方法。为了弄清无桥水树生长的时间变化规律,利用专用的实验室和装置,对LDPE板材在盐水溶液中浸泡300小时的高压应用试验进行了耗散电流波形监测,试验频率为1 kHz,电压为2 kVrms。高压应用试验结果证实,耗散电流三次谐波相位的电场依赖性与无桥水树的劣化率密切相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dissipation Current Waveforms Monitoring under Water Tree Deterioration Test of LDPE Sheet
The dissipation current waveform observation method is considered one of possible way as a diagnostic method for the un-bridged water tree on the high-voltage class power cable. In this paper, in order to clarify the time variations with the un-bridged water tree growth, by using the special chamber and setup, the dissipation current waveforms monitoring under the high voltage application test of LDPE sheet with soaking the sample into the saline solution was carried out at the applied frequency 1 kHz and applied voltage 2 kVrms for 300 hours. As the results of the high voltage application test, it was confirmed that the electric field dependence of the phase of 3rd harmonic of dissipation current strongly related with the deterioration rate of un-bridged water tree.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信