A. Djordjević, D. Olćan, J. Petrovic, N. Obradović, S. Filipović
{"title":"为介电参数的射频测量量身定制的高精度准静态旋转体数值模型","authors":"A. Djordjević, D. Olćan, J. Petrovic, N. Obradović, S. Filipović","doi":"10.2298/fuee2101141d","DOIUrl":null,"url":null,"abstract":"We have developed rotationally symmetrical coaxial chambers for measurements of dielectric parameters of disk-shaped samples, in the frequency range from 1 MHz to several hundred MHz. The reflection coefficient of the chamber is measured and the dielectric parameters are hence extracted utilizing a high-accuracy quasistatic numerical model of the chamber and the sample. We present this model, which is based on the method of-moments solution of a set of integral equations for composite metallic and dielectric bodies. The equations are tailored to bodies of revolution. The model is efficient and accurate so that the major contribution of the measurement uncertainty comes from the measurement hardware.","PeriodicalId":44296,"journal":{"name":"Facta Universitatis-Series Electronics and Energetics","volume":"24 3 1","pages":""},"PeriodicalIF":0.6000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High-accuracy quasistatic numerical model for bodies of revolution tailored for RF measurements of dielectric parameters\",\"authors\":\"A. Djordjević, D. Olćan, J. Petrovic, N. Obradović, S. Filipović\",\"doi\":\"10.2298/fuee2101141d\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have developed rotationally symmetrical coaxial chambers for measurements of dielectric parameters of disk-shaped samples, in the frequency range from 1 MHz to several hundred MHz. The reflection coefficient of the chamber is measured and the dielectric parameters are hence extracted utilizing a high-accuracy quasistatic numerical model of the chamber and the sample. We present this model, which is based on the method of-moments solution of a set of integral equations for composite metallic and dielectric bodies. The equations are tailored to bodies of revolution. The model is efficient and accurate so that the major contribution of the measurement uncertainty comes from the measurement hardware.\",\"PeriodicalId\":44296,\"journal\":{\"name\":\"Facta Universitatis-Series Electronics and Energetics\",\"volume\":\"24 3 1\",\"pages\":\"\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Facta Universitatis-Series Electronics and Energetics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2298/fuee2101141d\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Facta Universitatis-Series Electronics and Energetics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2298/fuee2101141d","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
High-accuracy quasistatic numerical model for bodies of revolution tailored for RF measurements of dielectric parameters
We have developed rotationally symmetrical coaxial chambers for measurements of dielectric parameters of disk-shaped samples, in the frequency range from 1 MHz to several hundred MHz. The reflection coefficient of the chamber is measured and the dielectric parameters are hence extracted utilizing a high-accuracy quasistatic numerical model of the chamber and the sample. We present this model, which is based on the method of-moments solution of a set of integral equations for composite metallic and dielectric bodies. The equations are tailored to bodies of revolution. The model is efficient and accurate so that the major contribution of the measurement uncertainty comes from the measurement hardware.