{"title":"视网膜图像中小动脉与静脉比值的自动估计方法","authors":"B. Dashtbozorg, A. Mendonça, A. Campilho","doi":"10.1109/CBMS.2013.6627854","DOIUrl":null,"url":null,"abstract":"This paper presents an automatic approach for the estimation of Arteriolar-to-Venular Ratio (AVR) in retinal images. The method was assessed using the images of the INSPIRE-AVR database. A mean error of 0.05 was obtained when the method's results were compared with reference AVR values provided with this dataset, thus demonstrating the adequacy of the proposed solution for AVR estimation.","PeriodicalId":20519,"journal":{"name":"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems","volume":"11 1","pages":"512-513"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"An automatic method for the estimation of Arteriolar-to-Venular Ratio in retinal images\",\"authors\":\"B. Dashtbozorg, A. Mendonça, A. Campilho\",\"doi\":\"10.1109/CBMS.2013.6627854\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an automatic approach for the estimation of Arteriolar-to-Venular Ratio (AVR) in retinal images. The method was assessed using the images of the INSPIRE-AVR database. A mean error of 0.05 was obtained when the method's results were compared with reference AVR values provided with this dataset, thus demonstrating the adequacy of the proposed solution for AVR estimation.\",\"PeriodicalId\":20519,\"journal\":{\"name\":\"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems\",\"volume\":\"11 1\",\"pages\":\"512-513\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CBMS.2013.6627854\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 26th IEEE International Symposium on Computer-Based Medical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CBMS.2013.6627854","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An automatic method for the estimation of Arteriolar-to-Venular Ratio in retinal images
This paper presents an automatic approach for the estimation of Arteriolar-to-Venular Ratio (AVR) in retinal images. The method was assessed using the images of the INSPIRE-AVR database. A mean error of 0.05 was obtained when the method's results were compared with reference AVR values provided with this dataset, thus demonstrating the adequacy of the proposed solution for AVR estimation.