冷凝器式换热器的耗火经济性分析

Ahmet Can , Ertan Buyruk , Dogan Eryener
{"title":"冷凝器式换热器的耗火经济性分析","authors":"Ahmet Can ,&nbsp;Ertan Buyruk ,&nbsp;Dogan Eryener","doi":"10.1016/S1164-0235(01)00051-6","DOIUrl":null,"url":null,"abstract":"<div><p>In this study, an exergoeconomic analysis of condenser type parallel flow heat exchangers is presented. Exergy losses of the heat exchanger and investment and operation expenses related to this are determined with functions of steam mass flow rate and water exit temperature at constant values of thermal power of the heat exchanger at 75240 W, cold water mass flow rate and temperature. The inlet temperature of water is 18<!--> <!-->°C and exit temperatures of water are varied from 25<!--> <!-->°C to 36<!--> <!-->°C. The values of temperature and pressure of saturated steam in the condenser are given to be <em>T</em><sub>con</sub>=47<!--> <!-->° C and <em>P</em><sub>con</sub>=10.53 kPa. Constant environment conditions are assumed. Annual operation hour and unit price of electrical energy are taken into account for determination of the annual operation expenses. Investment expenses are obtained according to the variation of heat capacity rate and logarithmic mean temperature difference and also heat exchanger dimension determined for each situation. The present analysis is hoped to be useful in determining the effective parameters for the most appropriate exergy losses together with operating conditions and in finding the optimum working points for the condenser type heat exchangers.</p></div>","PeriodicalId":100518,"journal":{"name":"Exergy, An International Journal","volume":"2 2","pages":"Pages 113-118"},"PeriodicalIF":0.0000,"publicationDate":"2002-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1164-0235(01)00051-6","citationCount":"25","resultStr":"{\"title\":\"Exergoeconomic analysis of condenser type heat exchangers\",\"authors\":\"Ahmet Can ,&nbsp;Ertan Buyruk ,&nbsp;Dogan Eryener\",\"doi\":\"10.1016/S1164-0235(01)00051-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this study, an exergoeconomic analysis of condenser type parallel flow heat exchangers is presented. Exergy losses of the heat exchanger and investment and operation expenses related to this are determined with functions of steam mass flow rate and water exit temperature at constant values of thermal power of the heat exchanger at 75240 W, cold water mass flow rate and temperature. The inlet temperature of water is 18<!--> <!-->°C and exit temperatures of water are varied from 25<!--> <!-->°C to 36<!--> <!-->°C. The values of temperature and pressure of saturated steam in the condenser are given to be <em>T</em><sub>con</sub>=47<!--> <!-->° C and <em>P</em><sub>con</sub>=10.53 kPa. Constant environment conditions are assumed. Annual operation hour and unit price of electrical energy are taken into account for determination of the annual operation expenses. Investment expenses are obtained according to the variation of heat capacity rate and logarithmic mean temperature difference and also heat exchanger dimension determined for each situation. The present analysis is hoped to be useful in determining the effective parameters for the most appropriate exergy losses together with operating conditions and in finding the optimum working points for the condenser type heat exchangers.</p></div>\",\"PeriodicalId\":100518,\"journal\":{\"name\":\"Exergy, An International Journal\",\"volume\":\"2 2\",\"pages\":\"Pages 113-118\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S1164-0235(01)00051-6\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Exergy, An International Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1164023501000516\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Exergy, An International Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1164023501000516","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

摘要

本文对冷凝器式平行流换热器进行了耗力经济分析。换热器的火用损失及与此相关的投资和运行费用由换热器热功率75240w定值时的蒸汽质量流量和出水温度、冷水质量流量和温度的函数确定。进水温度为18℃,出水温度为25℃~ 36℃。冷凝器饱和蒸汽的温度和压力分别为Tcon=47℃和Pcon=10.53 kPa。假设恒定的环境条件。年运行费用的确定考虑了年运行小时数和电能单价。投资费用根据热容量率和对数平均温差的变化以及每种情况下换热器的尺寸来确定。本文的分析对确定最适宜的火用损失和运行条件的有效参数以及找到冷凝器式换热器的最佳工作点有一定的帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Exergoeconomic analysis of condenser type heat exchangers

In this study, an exergoeconomic analysis of condenser type parallel flow heat exchangers is presented. Exergy losses of the heat exchanger and investment and operation expenses related to this are determined with functions of steam mass flow rate and water exit temperature at constant values of thermal power of the heat exchanger at 75240 W, cold water mass flow rate and temperature. The inlet temperature of water is 18 °C and exit temperatures of water are varied from 25 °C to 36 °C. The values of temperature and pressure of saturated steam in the condenser are given to be Tcon=47 ° C and Pcon=10.53 kPa. Constant environment conditions are assumed. Annual operation hour and unit price of electrical energy are taken into account for determination of the annual operation expenses. Investment expenses are obtained according to the variation of heat capacity rate and logarithmic mean temperature difference and also heat exchanger dimension determined for each situation. The present analysis is hoped to be useful in determining the effective parameters for the most appropriate exergy losses together with operating conditions and in finding the optimum working points for the condenser type heat exchangers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信