Seung-Ro Lee, T. Hizawa, K. Sawada, H. Takao, M. Ishida
{"title":"采用电荷传递技术的高性能血糖传感器","authors":"Seung-Ro Lee, T. Hizawa, K. Sawada, H. Takao, M. Ishida","doi":"10.1109/SENSOR.2007.4300265","DOIUrl":null,"url":null,"abstract":"The charge transfer type blood glucose sensor (CTTGS) has been proposed. The CTTGS is an accumulation method H+ ion (gluconic acid) perception system. As compared to cyclic-voltammetry and ISFET, the performance was found to be excellent with span and range of 1445 mV and 200 mmol/L respectively. The sensitivity obtained for blood glucose level of the person was 29.06 mV/mmol with a non-linear error of 1%, which is acceptable for clinical application.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"3 1","pages":"855-858"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High Performance Blood Glucose Sensor using Charge Transfer Technique\",\"authors\":\"Seung-Ro Lee, T. Hizawa, K. Sawada, H. Takao, M. Ishida\",\"doi\":\"10.1109/SENSOR.2007.4300265\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The charge transfer type blood glucose sensor (CTTGS) has been proposed. The CTTGS is an accumulation method H+ ion (gluconic acid) perception system. As compared to cyclic-voltammetry and ISFET, the performance was found to be excellent with span and range of 1445 mV and 200 mmol/L respectively. The sensitivity obtained for blood glucose level of the person was 29.06 mV/mmol with a non-linear error of 1%, which is acceptable for clinical application.\",\"PeriodicalId\":23295,\"journal\":{\"name\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"volume\":\"3 1\",\"pages\":\"855-858\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2007.4300265\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2007.4300265","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
High Performance Blood Glucose Sensor using Charge Transfer Technique
The charge transfer type blood glucose sensor (CTTGS) has been proposed. The CTTGS is an accumulation method H+ ion (gluconic acid) perception system. As compared to cyclic-voltammetry and ISFET, the performance was found to be excellent with span and range of 1445 mV and 200 mmol/L respectively. The sensitivity obtained for blood glucose level of the person was 29.06 mV/mmol with a non-linear error of 1%, which is acceptable for clinical application.