热分析技术及样品杯的现状与发展

Chen Li, Dayong Li, D. Shi, B. Lu
{"title":"热分析技术及样品杯的现状与发展","authors":"Chen Li, Dayong Li, D. Shi, B. Lu","doi":"10.1109/IFOST.2011.6020978","DOIUrl":null,"url":null,"abstract":"In this paper, the basic principles of thermal analysis and the structure of thermal analysis device are briefly reviewed. The structure and properties of thermal analysis sample cup made of different materials and temperature sensor are summarized, and their advantages and disadvantages are indicated. Also, the thermocouple sample cup made of resin sand and thermocouple sample cup made of graphite are described in detail. Thermal analysis device is mainly composed of the sample cup and data acquisition and processing system, and the thermocouples are pre-embedded in the cup to monitor the temperature. The resin sand cup is widely used while it is disposable. Although the graphite sample cup and Cu sample cup can be reused, they can only be used in the thermal analysis of aluminum alloys.","PeriodicalId":20466,"journal":{"name":"Proceedings of 2011 6th International Forum on Strategic Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Current situation and development of thermal analysis technology and sample cup\",\"authors\":\"Chen Li, Dayong Li, D. Shi, B. Lu\",\"doi\":\"10.1109/IFOST.2011.6020978\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the basic principles of thermal analysis and the structure of thermal analysis device are briefly reviewed. The structure and properties of thermal analysis sample cup made of different materials and temperature sensor are summarized, and their advantages and disadvantages are indicated. Also, the thermocouple sample cup made of resin sand and thermocouple sample cup made of graphite are described in detail. Thermal analysis device is mainly composed of the sample cup and data acquisition and processing system, and the thermocouples are pre-embedded in the cup to monitor the temperature. The resin sand cup is widely used while it is disposable. Although the graphite sample cup and Cu sample cup can be reused, they can only be used in the thermal analysis of aluminum alloys.\",\"PeriodicalId\":20466,\"journal\":{\"name\":\"Proceedings of 2011 6th International Forum on Strategic Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-09-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 2011 6th International Forum on Strategic Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IFOST.2011.6020978\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 2011 6th International Forum on Strategic Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IFOST.2011.6020978","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文简要介绍了热分析的基本原理和热分析装置的结构。总结了不同材料和温度传感器制成的热分析样品杯的结构和性能,指出了它们的优缺点。详细介绍了树脂砂热电偶样品杯和石墨热电偶样品杯。热分析装置主要由样品杯和数据采集处理系统组成,热电偶预嵌在样品杯中监测温度。树脂砂杯在一次性使用的同时被广泛使用。虽然石墨样品杯和铜样品杯可以重复使用,但它们只能用于铝合金的热分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Current situation and development of thermal analysis technology and sample cup
In this paper, the basic principles of thermal analysis and the structure of thermal analysis device are briefly reviewed. The structure and properties of thermal analysis sample cup made of different materials and temperature sensor are summarized, and their advantages and disadvantages are indicated. Also, the thermocouple sample cup made of resin sand and thermocouple sample cup made of graphite are described in detail. Thermal analysis device is mainly composed of the sample cup and data acquisition and processing system, and the thermocouples are pre-embedded in the cup to monitor the temperature. The resin sand cup is widely used while it is disposable. Although the graphite sample cup and Cu sample cup can be reused, they can only be used in the thermal analysis of aluminum alloys.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信