{"title":"基于深度迁移学习的胸部CT图像Covid-19检测","authors":"A. Irsyad, H. Tjandrasa","doi":"10.1109/ICTS52701.2021.9608160","DOIUrl":null,"url":null,"abstract":"Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is the virus that causes Covid-19. Covid-19 can spread quickly and lead to death so that the World Health Organization (WHO) has declared this disease a pandemic. Currently there are two methods commonly used in Covid-19, The Rapid Diagnostic Test (RDT) which has lower accuracy but requires fast time, and Real-Time Reverse Transcription Polymerase Chain Reaction (RT-PCR) which takes a long time but the accuracy is better than RDT. An alternative method that requires a short time and has high accuracy is required. One of method offered is to use CT images to detect Covid-19. This research proposes to detect Covid-19 from CT images using transfer learning methods of AlexNet, Resnet50, VGG16, Inception-v3, Inception-Resnet, Xception, and DenseNet. In this study we compared transfer learning using CLAHE preprocessing and without CLAHE. The results of this study provide that transfer learning with CLAHE preprocessing has a better performance than without CLAHE. The best performance has an accuracy of 94.97%, F-measure of 94.87%, and a precision of 97.88% for VGG16. Meanwhile, based on recall, Inception-Resnet has the best score with 95.62%, compared to VGG16 without CLAHE the results are slightly below the performance with 94.36% accuracy, F-measure of 94.21%, and a precision of 97.85, and the best recall is Resnet50 with 91.63%.","PeriodicalId":6738,"journal":{"name":"2021 13th International Conference on Information & Communication Technology and System (ICTS)","volume":"10 1","pages":"167-172"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Detection of Covid-19 from Chest CT Images Using Deep Transfer Learning\",\"authors\":\"A. Irsyad, H. Tjandrasa\",\"doi\":\"10.1109/ICTS52701.2021.9608160\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is the virus that causes Covid-19. Covid-19 can spread quickly and lead to death so that the World Health Organization (WHO) has declared this disease a pandemic. Currently there are two methods commonly used in Covid-19, The Rapid Diagnostic Test (RDT) which has lower accuracy but requires fast time, and Real-Time Reverse Transcription Polymerase Chain Reaction (RT-PCR) which takes a long time but the accuracy is better than RDT. An alternative method that requires a short time and has high accuracy is required. One of method offered is to use CT images to detect Covid-19. This research proposes to detect Covid-19 from CT images using transfer learning methods of AlexNet, Resnet50, VGG16, Inception-v3, Inception-Resnet, Xception, and DenseNet. In this study we compared transfer learning using CLAHE preprocessing and without CLAHE. The results of this study provide that transfer learning with CLAHE preprocessing has a better performance than without CLAHE. The best performance has an accuracy of 94.97%, F-measure of 94.87%, and a precision of 97.88% for VGG16. Meanwhile, based on recall, Inception-Resnet has the best score with 95.62%, compared to VGG16 without CLAHE the results are slightly below the performance with 94.36% accuracy, F-measure of 94.21%, and a precision of 97.85, and the best recall is Resnet50 with 91.63%.\",\"PeriodicalId\":6738,\"journal\":{\"name\":\"2021 13th International Conference on Information & Communication Technology and System (ICTS)\",\"volume\":\"10 1\",\"pages\":\"167-172\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 13th International Conference on Information & Communication Technology and System (ICTS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICTS52701.2021.9608160\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 13th International Conference on Information & Communication Technology and System (ICTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICTS52701.2021.9608160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Detection of Covid-19 from Chest CT Images Using Deep Transfer Learning
Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is the virus that causes Covid-19. Covid-19 can spread quickly and lead to death so that the World Health Organization (WHO) has declared this disease a pandemic. Currently there are two methods commonly used in Covid-19, The Rapid Diagnostic Test (RDT) which has lower accuracy but requires fast time, and Real-Time Reverse Transcription Polymerase Chain Reaction (RT-PCR) which takes a long time but the accuracy is better than RDT. An alternative method that requires a short time and has high accuracy is required. One of method offered is to use CT images to detect Covid-19. This research proposes to detect Covid-19 from CT images using transfer learning methods of AlexNet, Resnet50, VGG16, Inception-v3, Inception-Resnet, Xception, and DenseNet. In this study we compared transfer learning using CLAHE preprocessing and without CLAHE. The results of this study provide that transfer learning with CLAHE preprocessing has a better performance than without CLAHE. The best performance has an accuracy of 94.97%, F-measure of 94.87%, and a precision of 97.88% for VGG16. Meanwhile, based on recall, Inception-Resnet has the best score with 95.62%, compared to VGG16 without CLAHE the results are slightly below the performance with 94.36% accuracy, F-measure of 94.21%, and a precision of 97.85, and the best recall is Resnet50 with 91.63%.