C. Ferrarello, M. Campa, H. G. Infante, M. L. F. Sánchez, A. Sanz-Medel
{"title":"用hplc - icp - ms改进兔肝金属硫蛋白的分离:与传统阴离子交换色谱法的比较","authors":"C. Ferrarello, M. Campa, H. G. Infante, M. L. F. Sánchez, A. Sanz-Medel","doi":"10.1051/ANALUSIS:2000280351","DOIUrl":null,"url":null,"abstract":"The analytical performance of the Fast - Protein Liquid Chromatography (FPLC) (on a Mono Q HR 5/5 column) and the conventional AnionExchange Chromatography (on a Protein Pak DEAE 5PW column) to realise rabbit liver metallothioneins separations and Cd speciation has been investigated and the results are compared. The Mono Q column was found to provide higher resolution and reproducibility in shorter separation times than Protein Pak DEAE 5PW, a conventional anion-exchange column. Thus, FPLC is proposed as a very useful tool for the study of the polymorphism of metallothioneins.","PeriodicalId":8221,"journal":{"name":"Analusis","volume":"24 1","pages":"351-357"},"PeriodicalIF":0.0000,"publicationDate":"2000-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Improved separation of rabbit liver metallothioneins by FPLC-ICP-MS: a comparison with the conventional anion-exchange chromatography\",\"authors\":\"C. Ferrarello, M. Campa, H. G. Infante, M. L. F. Sánchez, A. Sanz-Medel\",\"doi\":\"10.1051/ANALUSIS:2000280351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The analytical performance of the Fast - Protein Liquid Chromatography (FPLC) (on a Mono Q HR 5/5 column) and the conventional AnionExchange Chromatography (on a Protein Pak DEAE 5PW column) to realise rabbit liver metallothioneins separations and Cd speciation has been investigated and the results are compared. The Mono Q column was found to provide higher resolution and reproducibility in shorter separation times than Protein Pak DEAE 5PW, a conventional anion-exchange column. Thus, FPLC is proposed as a very useful tool for the study of the polymorphism of metallothioneins.\",\"PeriodicalId\":8221,\"journal\":{\"name\":\"Analusis\",\"volume\":\"24 1\",\"pages\":\"351-357\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analusis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1051/ANALUSIS:2000280351\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analusis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ANALUSIS:2000280351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10
摘要
研究了快速蛋白液相色谱法(Mono Q HR 5/5色谱柱)和传统阴离子交换色谱法(Protein Pak DEAE 5PW色谱柱)分离兔肝脏金属硫蛋白和Cd形态的分析性能,并对结果进行了比较。与传统的阴离子交换柱Protein Pak DEAE 5PW相比,Mono Q柱在更短的分离时间内具有更高的分辨率和重现性。因此,FPLC被认为是研究金属硫蛋白多态性的一个非常有用的工具。
Improved separation of rabbit liver metallothioneins by FPLC-ICP-MS: a comparison with the conventional anion-exchange chromatography
The analytical performance of the Fast - Protein Liquid Chromatography (FPLC) (on a Mono Q HR 5/5 column) and the conventional AnionExchange Chromatography (on a Protein Pak DEAE 5PW column) to realise rabbit liver metallothioneins separations and Cd speciation has been investigated and the results are compared. The Mono Q column was found to provide higher resolution and reproducibility in shorter separation times than Protein Pak DEAE 5PW, a conventional anion-exchange column. Thus, FPLC is proposed as a very useful tool for the study of the polymorphism of metallothioneins.