浸入真空容器中的大型负离子源

Y. Oka, Y. Takeiri, O. Kaneko, A. Ando, K. Tsumori, R. Akiyama, T. Kawamoto, T. Kuroda
{"title":"浸入真空容器中的大型负离子源","authors":"Y. Oka, Y. Takeiri, O. Kaneko, A. Ando, K. Tsumori, R. Akiyama, T. Kawamoto, T. Kuroda","doi":"10.1063/1.1145054","DOIUrl":null,"url":null,"abstract":"To develop the powerful negative‐ion‐based neutral beam injection system for the large helical device, a 1/3 scaled H− source has been tested, which is immersed in the vacuum vessel. Intrinsic features of the vacuum‐immersed large H− source are described. Plasma density of higher than about 1012 e/cm3 is produced. During the beam extraction, it was found that a beam‐induced thin plasma exists in the vacuum vessel. In order to get a long pulse beam, this plasma was shielded and then the beam conditioning was completed up to the total beam energy of 70 keV for 100 ms, with the arc power up to about 50 kW. It is confirmed that H− current scaling as well as the plasma parameters would be similar to the scaling which is achieved by the previous 1/3 source.","PeriodicalId":7974,"journal":{"name":"Annual Report of National Institute for Fusion Science","volume":"163 1","pages":"65"},"PeriodicalIF":0.0000,"publicationDate":"1994-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A Large Negative Ion Source Immersed in the Vacuum Vessel\",\"authors\":\"Y. Oka, Y. Takeiri, O. Kaneko, A. Ando, K. Tsumori, R. Akiyama, T. Kawamoto, T. Kuroda\",\"doi\":\"10.1063/1.1145054\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To develop the powerful negative‐ion‐based neutral beam injection system for the large helical device, a 1/3 scaled H− source has been tested, which is immersed in the vacuum vessel. Intrinsic features of the vacuum‐immersed large H− source are described. Plasma density of higher than about 1012 e/cm3 is produced. During the beam extraction, it was found that a beam‐induced thin plasma exists in the vacuum vessel. In order to get a long pulse beam, this plasma was shielded and then the beam conditioning was completed up to the total beam energy of 70 keV for 100 ms, with the arc power up to about 50 kW. It is confirmed that H− current scaling as well as the plasma parameters would be similar to the scaling which is achieved by the previous 1/3 source.\",\"PeriodicalId\":7974,\"journal\":{\"name\":\"Annual Report of National Institute for Fusion Science\",\"volume\":\"163 1\",\"pages\":\"65\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annual Report of National Institute for Fusion Science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/1.1145054\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual Report of National Institute for Fusion Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/1.1145054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

为了开发用于大型螺旋装置的强大的负离子基中性束注入系统,在真空容器中对1/3比例的H -源进行了测试。描述了真空浸没大氢源的固有特征。等离子体密度高于约1012 e/cm3。在抽束过程中,发现真空容器中存在束致薄等离子体。为了获得长脉冲光束,对等离子体进行屏蔽,然后对光束进行调理,使光束总能量达到70 keV,持续100 ms,电弧功率约为50 kW。证实了H -电流的标度以及等离子体参数与之前的1/3源的标度相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Large Negative Ion Source Immersed in the Vacuum Vessel
To develop the powerful negative‐ion‐based neutral beam injection system for the large helical device, a 1/3 scaled H− source has been tested, which is immersed in the vacuum vessel. Intrinsic features of the vacuum‐immersed large H− source are described. Plasma density of higher than about 1012 e/cm3 is produced. During the beam extraction, it was found that a beam‐induced thin plasma exists in the vacuum vessel. In order to get a long pulse beam, this plasma was shielded and then the beam conditioning was completed up to the total beam energy of 70 keV for 100 ms, with the arc power up to about 50 kW. It is confirmed that H− current scaling as well as the plasma parameters would be similar to the scaling which is achieved by the previous 1/3 source.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信