逆变站交流故障时串联多端高压直流的动态性能

Xiaobo Yang, Chunming Yuan, D. Yao, Chao Yang, Chengyan Yue
{"title":"逆变站交流故障时串联多端高压直流的动态性能","authors":"Xiaobo Yang, Chunming Yuan, D. Yao, Chao Yang, Chengyan Yue","doi":"10.1109/EPE.2014.6910817","DOIUrl":null,"url":null,"abstract":"Multiterminal high voltage direct current (MTDC) system can be either a series type or a parallel type. Series MTDC concept is essentially developed from the two-terminal HVDC but with some unique characteristics. In this paper, the AC fault ride through capability of series MTDC is discussed. AC faults at inverter stations, which are connected to electrically separated AC systems, will be highlighted. For an AC fault that happens at one inverter station, the DC voltage of that station may decrease to zero due to commutation failure, while the other inverter stations (the healthy inverters) can still retain power transmission capability to some extent, which will increase the availability of the series MTDC system. However, the current controller design, the voltage dependent current order limiter (VDCOL) logic and the AC system strength will impact on the dynamic performance of series MTDC during AC faults. In this paper, a + 800kV/3.2GW 4-terminal line commutated converter (LCC) based series MTDC model is established to study the dynamic performance when AC faults occur at an inverter. The controller of the series MTDC is designed; the VDCOL logic for series MTDC is developed; simulation results of the dynamic performance during AC faults at the inverter stations are presented.","PeriodicalId":6508,"journal":{"name":"2014 16th European Conference on Power Electronics and Applications","volume":"115 1","pages":"1-9"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Dynamic performance of series multiterminal HVDC during AC faults at inverter stations\",\"authors\":\"Xiaobo Yang, Chunming Yuan, D. Yao, Chao Yang, Chengyan Yue\",\"doi\":\"10.1109/EPE.2014.6910817\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Multiterminal high voltage direct current (MTDC) system can be either a series type or a parallel type. Series MTDC concept is essentially developed from the two-terminal HVDC but with some unique characteristics. In this paper, the AC fault ride through capability of series MTDC is discussed. AC faults at inverter stations, which are connected to electrically separated AC systems, will be highlighted. For an AC fault that happens at one inverter station, the DC voltage of that station may decrease to zero due to commutation failure, while the other inverter stations (the healthy inverters) can still retain power transmission capability to some extent, which will increase the availability of the series MTDC system. However, the current controller design, the voltage dependent current order limiter (VDCOL) logic and the AC system strength will impact on the dynamic performance of series MTDC during AC faults. In this paper, a + 800kV/3.2GW 4-terminal line commutated converter (LCC) based series MTDC model is established to study the dynamic performance when AC faults occur at an inverter. The controller of the series MTDC is designed; the VDCOL logic for series MTDC is developed; simulation results of the dynamic performance during AC faults at the inverter stations are presented.\",\"PeriodicalId\":6508,\"journal\":{\"name\":\"2014 16th European Conference on Power Electronics and Applications\",\"volume\":\"115 1\",\"pages\":\"1-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 16th European Conference on Power Electronics and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE.2014.6910817\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 16th European Conference on Power Electronics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE.2014.6910817","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

多端子高压直流(MTDC)系统可以是串联型的,也可以是并联型的。串联MTDC的概念本质上是由双端高压直流发展而来的,但具有一些独特的特点。本文讨论了串联MTDC的交流故障穿越能力。逆变器站的交流故障,连接到电气分离的交流系统,将被强调。当一个逆变站发生交流故障时,该逆变站的直流电压可能因换相失效而降至零,而其他逆变站(健康逆变器)仍能在一定程度上保留输电能力,这将增加串联MTDC系统的可用性。然而,电流控制器的设计、电压相关限流器(VDCOL)逻辑以及交流系统的强度都会影响串联MTDC在交流故障时的动态性能。本文建立了基于+ 800kV/3.2GW 4端线路换向变流器(LCC)的串联MTDC模型,研究逆变器发生交流故障时的动态性能。设计了系列MTDC的控制器;开发了串联MTDC的VDCOL逻辑;给出了逆变站交流故障时动态性能的仿真结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Dynamic performance of series multiterminal HVDC during AC faults at inverter stations
Multiterminal high voltage direct current (MTDC) system can be either a series type or a parallel type. Series MTDC concept is essentially developed from the two-terminal HVDC but with some unique characteristics. In this paper, the AC fault ride through capability of series MTDC is discussed. AC faults at inverter stations, which are connected to electrically separated AC systems, will be highlighted. For an AC fault that happens at one inverter station, the DC voltage of that station may decrease to zero due to commutation failure, while the other inverter stations (the healthy inverters) can still retain power transmission capability to some extent, which will increase the availability of the series MTDC system. However, the current controller design, the voltage dependent current order limiter (VDCOL) logic and the AC system strength will impact on the dynamic performance of series MTDC during AC faults. In this paper, a + 800kV/3.2GW 4-terminal line commutated converter (LCC) based series MTDC model is established to study the dynamic performance when AC faults occur at an inverter. The controller of the series MTDC is designed; the VDCOL logic for series MTDC is developed; simulation results of the dynamic performance during AC faults at the inverter stations are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信