负载对成网逆变器动力学影响的频响分析

M. Berg, T. Messo, T. Suntio
{"title":"负载对成网逆变器动力学影响的频响分析","authors":"M. Berg, T. Messo, T. Suntio","doi":"10.23919/IPEC.2018.8507820","DOIUrl":null,"url":null,"abstract":"The grid-forming mode of the voltage source inverters (VSI) is applied in uninterruptible power supplies and micro-grids to improve the reliability of electricity distribution. During the intentional islanding of an inverter-based micro-grid, the grid-forming inverters (GFI) are responsible for voltage control, similarly as in the case of uninterruptible power supplies (UPS). The unterminated model of GFI can be developed by considering the load as an ideal current sink. Thus, the load impedance always affects the dynamic behavior of the GFI. This paper proposes a method, to analyze how the dynamics of GFI and the controller design are affected by the load. Particularly, how the frequency response of the voltage loop gain changes according to the load and, how it can be used to the predict time-domain step response. The frequency responses that are measured from a hardware-in-the-loop simulator are used to verify and illustrate explicitly the load effect.","PeriodicalId":6610,"journal":{"name":"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)","volume":"34 1","pages":"963-970"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Frequency Response Analysis of Load Effect on Dynamics of Grid-Forming Inverter\",\"authors\":\"M. Berg, T. Messo, T. Suntio\",\"doi\":\"10.23919/IPEC.2018.8507820\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The grid-forming mode of the voltage source inverters (VSI) is applied in uninterruptible power supplies and micro-grids to improve the reliability of electricity distribution. During the intentional islanding of an inverter-based micro-grid, the grid-forming inverters (GFI) are responsible for voltage control, similarly as in the case of uninterruptible power supplies (UPS). The unterminated model of GFI can be developed by considering the load as an ideal current sink. Thus, the load impedance always affects the dynamic behavior of the GFI. This paper proposes a method, to analyze how the dynamics of GFI and the controller design are affected by the load. Particularly, how the frequency response of the voltage loop gain changes according to the load and, how it can be used to the predict time-domain step response. The frequency responses that are measured from a hardware-in-the-loop simulator are used to verify and illustrate explicitly the load effect.\",\"PeriodicalId\":6610,\"journal\":{\"name\":\"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)\",\"volume\":\"34 1\",\"pages\":\"963-970\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/IPEC.2018.8507820\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/IPEC.2018.8507820","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

电压源逆变器(VSI)的并网方式被应用于不间断电源和微电网,以提高配电的可靠性。在基于逆变器的微电网有意孤岛期间,并网逆变器(GFI)负责电压控制,类似于不间断电源(UPS)的情况。将负载视为理想的电流汇,可以建立GFI的无端接模型。因此,负载阻抗总是影响GFI的动态特性。本文提出了一种分析负载对GFI动力学和控制器设计影响的方法。特别是,电压环增益的频率响应如何随负载的变化而变化,以及如何将其用于预测时域阶跃响应。从硬件在环模拟器测量的频率响应用于验证和明确说明负载效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Frequency Response Analysis of Load Effect on Dynamics of Grid-Forming Inverter
The grid-forming mode of the voltage source inverters (VSI) is applied in uninterruptible power supplies and micro-grids to improve the reliability of electricity distribution. During the intentional islanding of an inverter-based micro-grid, the grid-forming inverters (GFI) are responsible for voltage control, similarly as in the case of uninterruptible power supplies (UPS). The unterminated model of GFI can be developed by considering the load as an ideal current sink. Thus, the load impedance always affects the dynamic behavior of the GFI. This paper proposes a method, to analyze how the dynamics of GFI and the controller design are affected by the load. Particularly, how the frequency response of the voltage loop gain changes according to the load and, how it can be used to the predict time-domain step response. The frequency responses that are measured from a hardware-in-the-loop simulator are used to verify and illustrate explicitly the load effect.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信