{"title":"基于TOA和rssi的无线胶囊内窥镜定位方法的性能比较","authors":"Takahiro Ito, D. Anzai, Jianqing Wang","doi":"10.1109/ISMICT.2015.7107515","DOIUrl":null,"url":null,"abstract":"A wireless capsule endoscope (WCE) is a promising medical device for diagnosis of digestive organs, which takes pictures inside digestive organs, such as large and small intestines and transmits them through implant wireless communications. In a realistic WCE scenario, it is important to precisely estimate the WCE location. Generally, the superiority of TOA-based localization over RSSI-based localization has been pointed out in many papers in wireless communication systems. However, because the propagation speed inside of a human body varies due to the influence of its biological tissues (namely, the relative permittivity of human tissues), the realization of precise TOA-based localization needs to accurately estimate the propagation velocity of implant communication signals. So, in this paper, we propose a TOA-based method for joint location/relative permittivity estimation, and then compare the performances between TOA- and RSSI-based WCE location estimation methods. Our computer simulation results reveal that, the TOA-based localization with accurate relative permittivity information outperforms the RSSI-based localization in terms of the localization accuracy, whereas the RSSI-based localization is advantageous if accurate relative permittivity is not obtained. Additionally, the proposed TOA-based localization can achieve not only better localization accuracy than that of the RSSI-based localization but also accurate averaged relative permittivity estimation.","PeriodicalId":6624,"journal":{"name":"2015 9th International Symposium on Medical Information and Communication Technology (ISMICT)","volume":"12 1","pages":"139-143"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Performance comparison between TOA- and RSSI-based localization methods for wireless capsule endoscopy systems\",\"authors\":\"Takahiro Ito, D. Anzai, Jianqing Wang\",\"doi\":\"10.1109/ISMICT.2015.7107515\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A wireless capsule endoscope (WCE) is a promising medical device for diagnosis of digestive organs, which takes pictures inside digestive organs, such as large and small intestines and transmits them through implant wireless communications. In a realistic WCE scenario, it is important to precisely estimate the WCE location. Generally, the superiority of TOA-based localization over RSSI-based localization has been pointed out in many papers in wireless communication systems. However, because the propagation speed inside of a human body varies due to the influence of its biological tissues (namely, the relative permittivity of human tissues), the realization of precise TOA-based localization needs to accurately estimate the propagation velocity of implant communication signals. So, in this paper, we propose a TOA-based method for joint location/relative permittivity estimation, and then compare the performances between TOA- and RSSI-based WCE location estimation methods. Our computer simulation results reveal that, the TOA-based localization with accurate relative permittivity information outperforms the RSSI-based localization in terms of the localization accuracy, whereas the RSSI-based localization is advantageous if accurate relative permittivity is not obtained. Additionally, the proposed TOA-based localization can achieve not only better localization accuracy than that of the RSSI-based localization but also accurate averaged relative permittivity estimation.\",\"PeriodicalId\":6624,\"journal\":{\"name\":\"2015 9th International Symposium on Medical Information and Communication Technology (ISMICT)\",\"volume\":\"12 1\",\"pages\":\"139-143\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 9th International Symposium on Medical Information and Communication Technology (ISMICT)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISMICT.2015.7107515\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 9th International Symposium on Medical Information and Communication Technology (ISMICT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISMICT.2015.7107515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance comparison between TOA- and RSSI-based localization methods for wireless capsule endoscopy systems
A wireless capsule endoscope (WCE) is a promising medical device for diagnosis of digestive organs, which takes pictures inside digestive organs, such as large and small intestines and transmits them through implant wireless communications. In a realistic WCE scenario, it is important to precisely estimate the WCE location. Generally, the superiority of TOA-based localization over RSSI-based localization has been pointed out in many papers in wireless communication systems. However, because the propagation speed inside of a human body varies due to the influence of its biological tissues (namely, the relative permittivity of human tissues), the realization of precise TOA-based localization needs to accurately estimate the propagation velocity of implant communication signals. So, in this paper, we propose a TOA-based method for joint location/relative permittivity estimation, and then compare the performances between TOA- and RSSI-based WCE location estimation methods. Our computer simulation results reveal that, the TOA-based localization with accurate relative permittivity information outperforms the RSSI-based localization in terms of the localization accuracy, whereas the RSSI-based localization is advantageous if accurate relative permittivity is not obtained. Additionally, the proposed TOA-based localization can achieve not only better localization accuracy than that of the RSSI-based localization but also accurate averaged relative permittivity estimation.