C. Nieto-Londoño, Carlos Andrés Bustamante-Chaverra, Jhon Anderson Buendía-García, L. Novoa, Joao Alexander García-Lázaro, Geoffrey Viviescas-Ibarra
{"title":"用于评估管道关闭和重新启动过程的瞬态热水力建模","authors":"C. Nieto-Londoño, Carlos Andrés Bustamante-Chaverra, Jhon Anderson Buendía-García, L. Novoa, Joao Alexander García-Lázaro, Geoffrey Viviescas-Ibarra","doi":"10.29047/01225383.179","DOIUrl":null,"url":null,"abstract":"In order to study shutdown and re-start in heavy crude oil pipelines, a model was developed. It simulates, in a transient state, the behavior of pressure, flow and temperature variables, averaged over the cross-sectional area and as a function of time and the axial coordinate. The model was validated with actual operational data from a test case. Results obtained for different operating points, stopping time, crude properties, topographies and lengths are presented. Additionally, the governing equations are converted to dimensionless expressions in order to obtain the dimensionless numbers relevant to the re-start operation for crude oil pipelines.","PeriodicalId":10745,"journal":{"name":"CT&F - Ciencia, Tecnología y Futuro","volume":"110 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermohydraulic modeling in transient state for evaluation of pipeline shutdown and restart procedures\",\"authors\":\"C. Nieto-Londoño, Carlos Andrés Bustamante-Chaverra, Jhon Anderson Buendía-García, L. Novoa, Joao Alexander García-Lázaro, Geoffrey Viviescas-Ibarra\",\"doi\":\"10.29047/01225383.179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to study shutdown and re-start in heavy crude oil pipelines, a model was developed. It simulates, in a transient state, the behavior of pressure, flow and temperature variables, averaged over the cross-sectional area and as a function of time and the axial coordinate. The model was validated with actual operational data from a test case. Results obtained for different operating points, stopping time, crude properties, topographies and lengths are presented. Additionally, the governing equations are converted to dimensionless expressions in order to obtain the dimensionless numbers relevant to the re-start operation for crude oil pipelines.\",\"PeriodicalId\":10745,\"journal\":{\"name\":\"CT&F - Ciencia, Tecnología y Futuro\",\"volume\":\"110 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CT&F - Ciencia, Tecnología y Futuro\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29047/01225383.179\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CT&F - Ciencia, Tecnología y Futuro","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29047/01225383.179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Thermohydraulic modeling in transient state for evaluation of pipeline shutdown and restart procedures
In order to study shutdown and re-start in heavy crude oil pipelines, a model was developed. It simulates, in a transient state, the behavior of pressure, flow and temperature variables, averaged over the cross-sectional area and as a function of time and the axial coordinate. The model was validated with actual operational data from a test case. Results obtained for different operating points, stopping time, crude properties, topographies and lengths are presented. Additionally, the governing equations are converted to dimensionless expressions in order to obtain the dimensionless numbers relevant to the re-start operation for crude oil pipelines.