{"title":"换流变压器绕组径向短路电动势的计算与分析","authors":"Zhong-cheng Zhao, Guan Wang, Suxian Liu, Liangkai Wang, Hongbin Wu","doi":"10.1109/AEERO52475.2021.9708164","DOIUrl":null,"url":null,"abstract":"For a 530KV/406MVA single-phase dual-winding converter transformer, according to its actual operating circuit, set a three-phase short-circuit fault to obtain the maximum short-circuit current. The finite element software comsol is used to build a two-dimensional axisymmetric model of the transformer, the leakage magnetic density and radial short-circuit electromotive force of the high and low voltage windings are obtained, and the radial steady-state check of the converter transformer is performed. The calculation and analysis results show that the model and calculation method can realize the calculation of the radial short-circuit force of the windings of the converter transformer and the calculation of the radial mechanical strength.","PeriodicalId":6828,"journal":{"name":"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)","volume":"25 2 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Calculation and Analysis of The Radial Short-circuit Electromotive Force of The Converter Transformer Winding\",\"authors\":\"Zhong-cheng Zhao, Guan Wang, Suxian Liu, Liangkai Wang, Hongbin Wu\",\"doi\":\"10.1109/AEERO52475.2021.9708164\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For a 530KV/406MVA single-phase dual-winding converter transformer, according to its actual operating circuit, set a three-phase short-circuit fault to obtain the maximum short-circuit current. The finite element software comsol is used to build a two-dimensional axisymmetric model of the transformer, the leakage magnetic density and radial short-circuit electromotive force of the high and low voltage windings are obtained, and the radial steady-state check of the converter transformer is performed. The calculation and analysis results show that the model and calculation method can realize the calculation of the radial short-circuit force of the windings of the converter transformer and the calculation of the radial mechanical strength.\",\"PeriodicalId\":6828,\"journal\":{\"name\":\"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)\",\"volume\":\"25 2 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEERO52475.2021.9708164\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEERO52475.2021.9708164","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对于530KV/406MVA单相双绕组换流变压器,根据其实际运行回路设置三相短路故障,以获得最大短路电流。利用有限元软件comsol建立了变压器的二维轴对称模型,得到了高、低压绕组的漏磁密度和径向短路电动势,并对换流变压器进行了径向稳态校核。计算分析结果表明,该模型和计算方法可以实现换流变压器绕组径向短路力的计算和径向机械强度的计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Calculation and Analysis of The Radial Short-circuit Electromotive Force of The Converter Transformer Winding
For a 530KV/406MVA single-phase dual-winding converter transformer, according to its actual operating circuit, set a three-phase short-circuit fault to obtain the maximum short-circuit current. The finite element software comsol is used to build a two-dimensional axisymmetric model of the transformer, the leakage magnetic density and radial short-circuit electromotive force of the high and low voltage windings are obtained, and the radial steady-state check of the converter transformer is performed. The calculation and analysis results show that the model and calculation method can realize the calculation of the radial short-circuit force of the windings of the converter transformer and the calculation of the radial mechanical strength.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信