A. Seshia, Moorthi Palaniapan, T. Roessig, R. Howe, R. Gooch, T. Schimert, Stephen Montague
{"title":"一种真空封装表面微机械谐振加速度计","authors":"A. Seshia, Moorthi Palaniapan, T. Roessig, R. Howe, R. Gooch, T. Schimert, Stephen Montague","doi":"10.1109/JMEMS.2002.805207","DOIUrl":null,"url":null,"abstract":"This paper describes the operation of a vacuum packaged resonant accelerometer subjected to static and dynamic acceleration testing. The device response is in broad agreement with a new analytical model of its behavior under an applied time-varying acceleration. Measurements include tests of the scale factor of the sensor and the dependence of the output sideband power and the noise floor of the double-ended tuning fork oscillators as a function of the applied acceleration frequency. The resolution of resonant accelerometers is shown to degrade 20 dB/decade beyond a certain characteristic acceleration corner frequency. A prototype device was fabricated at Sandia National Laboratories and exhibits a noise floor of 40 /spl mu/g//spl radic/(Hz) for an input acceleration frequency of 300 Hz.","PeriodicalId":13438,"journal":{"name":"IEEE\\/ASME Journal of Microelectromechanical Systems","volume":"148 1","pages":"784-793"},"PeriodicalIF":0.0000,"publicationDate":"2002-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"320","resultStr":"{\"title\":\"A vacuum packaged surface micromachined resonant accelerometer\",\"authors\":\"A. Seshia, Moorthi Palaniapan, T. Roessig, R. Howe, R. Gooch, T. Schimert, Stephen Montague\",\"doi\":\"10.1109/JMEMS.2002.805207\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper describes the operation of a vacuum packaged resonant accelerometer subjected to static and dynamic acceleration testing. The device response is in broad agreement with a new analytical model of its behavior under an applied time-varying acceleration. Measurements include tests of the scale factor of the sensor and the dependence of the output sideband power and the noise floor of the double-ended tuning fork oscillators as a function of the applied acceleration frequency. The resolution of resonant accelerometers is shown to degrade 20 dB/decade beyond a certain characteristic acceleration corner frequency. A prototype device was fabricated at Sandia National Laboratories and exhibits a noise floor of 40 /spl mu/g//spl radic/(Hz) for an input acceleration frequency of 300 Hz.\",\"PeriodicalId\":13438,\"journal\":{\"name\":\"IEEE\\\\/ASME Journal of Microelectromechanical Systems\",\"volume\":\"148 1\",\"pages\":\"784-793\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"320\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE\\\\/ASME Journal of Microelectromechanical Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/JMEMS.2002.805207\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE\\/ASME Journal of Microelectromechanical Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/JMEMS.2002.805207","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A vacuum packaged surface micromachined resonant accelerometer
This paper describes the operation of a vacuum packaged resonant accelerometer subjected to static and dynamic acceleration testing. The device response is in broad agreement with a new analytical model of its behavior under an applied time-varying acceleration. Measurements include tests of the scale factor of the sensor and the dependence of the output sideband power and the noise floor of the double-ended tuning fork oscillators as a function of the applied acceleration frequency. The resolution of resonant accelerometers is shown to degrade 20 dB/decade beyond a certain characteristic acceleration corner frequency. A prototype device was fabricated at Sandia National Laboratories and exhibits a noise floor of 40 /spl mu/g//spl radic/(Hz) for an input acceleration frequency of 300 Hz.