{"title":"动态监测心率响应式起搏器的活动传感器和算法比较","authors":"D. Cooper","doi":"10.1109/CIC.1993.378351","DOIUrl":null,"url":null,"abstract":"Various methods have been used to control rate-responsive pacemaker rates using activity as controlling signal. The purpose of this study was to compare the performance of two activity sensors (case-mounted piezoelectric and accelerometer), two bandpass filters (1-4 Hz and 15 Hz), and two signal processing algorithms (threshold counting and integration). Data were collected in 26 normal human subjects during protocols using treadmill, bicycle, and daily activity including driving a car. Performance was judged using the normal sinus rate as a standard. The accelerometer performed better than the case-mounted piezoelectric sensor (p<0.01). The threshold algorithm performed better than the signal integration algorithm using the accelerometer (p<0.05).<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"87 1","pages":"851-854"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Comparison of activity sensors and algorithms for rate-responsive pacemakers using ambulatory monitoring\",\"authors\":\"D. Cooper\",\"doi\":\"10.1109/CIC.1993.378351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Various methods have been used to control rate-responsive pacemaker rates using activity as controlling signal. The purpose of this study was to compare the performance of two activity sensors (case-mounted piezoelectric and accelerometer), two bandpass filters (1-4 Hz and 15 Hz), and two signal processing algorithms (threshold counting and integration). Data were collected in 26 normal human subjects during protocols using treadmill, bicycle, and daily activity including driving a car. Performance was judged using the normal sinus rate as a standard. The accelerometer performed better than the case-mounted piezoelectric sensor (p<0.01). The threshold algorithm performed better than the signal integration algorithm using the accelerometer (p<0.05).<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"87 1\",\"pages\":\"851-854\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378351\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison of activity sensors and algorithms for rate-responsive pacemakers using ambulatory monitoring
Various methods have been used to control rate-responsive pacemaker rates using activity as controlling signal. The purpose of this study was to compare the performance of two activity sensors (case-mounted piezoelectric and accelerometer), two bandpass filters (1-4 Hz and 15 Hz), and two signal processing algorithms (threshold counting and integration). Data were collected in 26 normal human subjects during protocols using treadmill, bicycle, and daily activity including driving a car. Performance was judged using the normal sinus rate as a standard. The accelerometer performed better than the case-mounted piezoelectric sensor (p<0.01). The threshold algorithm performed better than the signal integration algorithm using the accelerometer (p<0.05).<>