{"title":"对合成膜透析器的反应:发生率会增加吗?","authors":"J. Martín-Navarro, R. Esteras, Esmeralda Castillo, Sol Carriazo, Raul Fernandez-Prado, C. Gracia-Iguacel, Sebastián Más Fontao, A. Ortiz, E. González-Parra","doi":"10.1159/000501035","DOIUrl":null,"url":null,"abstract":"Background: Reactions to dialyzers used in dialysis have been reported more frequently in recent years. Evidence, however, shows that the reaction rate has remained stable for years. Summary: One explanation for the apparent increase in publication frequency could be the lack of knowledge that dialyzer reactions may well occur with biocompatible membranes. Studies showed that the cause of these reactions is very diverse and varied, involving multiple materials. However, polyvinylpyrrolidone continues to be the main suspect, but without conclusive results. There are no differences between the different fibers, and although polysulfone is the most described, it is also the most used. Key Messages: The change to cellulose triacetate continues to be the most appropriate form of treatment. The classification of these reactions into type A and B complicates the diagnosis, and its true usefulness is in doubt.","PeriodicalId":17810,"journal":{"name":"Kidney and Blood Pressure Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Reactions to Synthetic Membranes Dialyzers: Is there an Increase in Incidence?\",\"authors\":\"J. Martín-Navarro, R. Esteras, Esmeralda Castillo, Sol Carriazo, Raul Fernandez-Prado, C. Gracia-Iguacel, Sebastián Más Fontao, A. Ortiz, E. González-Parra\",\"doi\":\"10.1159/000501035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Reactions to dialyzers used in dialysis have been reported more frequently in recent years. Evidence, however, shows that the reaction rate has remained stable for years. Summary: One explanation for the apparent increase in publication frequency could be the lack of knowledge that dialyzer reactions may well occur with biocompatible membranes. Studies showed that the cause of these reactions is very diverse and varied, involving multiple materials. However, polyvinylpyrrolidone continues to be the main suspect, but without conclusive results. There are no differences between the different fibers, and although polysulfone is the most described, it is also the most used. Key Messages: The change to cellulose triacetate continues to be the most appropriate form of treatment. The classification of these reactions into type A and B complicates the diagnosis, and its true usefulness is in doubt.\",\"PeriodicalId\":17810,\"journal\":{\"name\":\"Kidney and Blood Pressure Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-09-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kidney and Blood Pressure Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000501035\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kidney and Blood Pressure Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000501035","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

背景:透析中使用的透析器的反应近年来报道较多。然而,有证据表明,反应速率多年来一直保持稳定。摘要:发表频率明显增加的一个解释可能是缺乏对生物相容性膜可能发生透析器反应的认识。研究表明,这些反应的原因非常多样,涉及多种物质。然而,聚乙烯吡咯烷酮仍然是主要的怀疑,但没有结论性的结果。不同纤维之间没有区别,尽管聚砜是描述最多的,但它也是使用最多的。关键信息:改为三醋酸纤维素仍然是最合适的处理形式。将这些反应分为A型和B型使诊断复杂化,其真正的用途也值得怀疑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reactions to Synthetic Membranes Dialyzers: Is there an Increase in Incidence?
Background: Reactions to dialyzers used in dialysis have been reported more frequently in recent years. Evidence, however, shows that the reaction rate has remained stable for years. Summary: One explanation for the apparent increase in publication frequency could be the lack of knowledge that dialyzer reactions may well occur with biocompatible membranes. Studies showed that the cause of these reactions is very diverse and varied, involving multiple materials. However, polyvinylpyrrolidone continues to be the main suspect, but without conclusive results. There are no differences between the different fibers, and although polysulfone is the most described, it is also the most used. Key Messages: The change to cellulose triacetate continues to be the most appropriate form of treatment. The classification of these reactions into type A and B complicates the diagnosis, and its true usefulness is in doubt.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信