基于单片多晶硅纳米线CMOS工艺的全集成乙型肝炎病毒DNA检测SoC

Che-Wei Huang, Yu-Jie Huang, Pei-Wen Yen, Hsiao-Ting Hsueh, Chia-Yi Lin, Min-Cheng Chen, C. Ho, Fu-Liang Yang, H. Tsai, H. Liao, Y. Juang, Chorng-Kuang Wang, Chih-Ting Lin, Shey-Shi Lu
{"title":"基于单片多晶硅纳米线CMOS工艺的全集成乙型肝炎病毒DNA检测SoC","authors":"Che-Wei Huang, Yu-Jie Huang, Pei-Wen Yen, Hsiao-Ting Hsueh, Chia-Yi Lin, Min-Cheng Chen, C. Ho, Fu-Liang Yang, H. Tsai, H. Liao, Y. Juang, Chorng-Kuang Wang, Chih-Ting Lin, Shey-Shi Lu","doi":"10.1109/VLSIC.2012.6243821","DOIUrl":null,"url":null,"abstract":"Polysilicon nanowire (poly-Si NW) based biosensor is integrated with the wireless acquisition circuits in a standard CMOS SoC for the first time. To improve detection quality, a chopper DDA-based analog front-end with features of low noise, high CMRR, and rail-to-rail input range is implemented. Additional temperature sensor is also included to compensate temperature drift of the biosensor. The results indicate that the detection limit is as low as 10fM. The capability to distinguish one base-pair mismatched DNAs is also demonstrated.","PeriodicalId":6347,"journal":{"name":"2012 Symposium on VLSI Circuits (VLSIC)","volume":"78 2 1","pages":"124-125"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"A fully integrated hepatitis B virus DNA detection SoC based on monolithic polysilicon nanowire CMOS process\",\"authors\":\"Che-Wei Huang, Yu-Jie Huang, Pei-Wen Yen, Hsiao-Ting Hsueh, Chia-Yi Lin, Min-Cheng Chen, C. Ho, Fu-Liang Yang, H. Tsai, H. Liao, Y. Juang, Chorng-Kuang Wang, Chih-Ting Lin, Shey-Shi Lu\",\"doi\":\"10.1109/VLSIC.2012.6243821\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Polysilicon nanowire (poly-Si NW) based biosensor is integrated with the wireless acquisition circuits in a standard CMOS SoC for the first time. To improve detection quality, a chopper DDA-based analog front-end with features of low noise, high CMRR, and rail-to-rail input range is implemented. Additional temperature sensor is also included to compensate temperature drift of the biosensor. The results indicate that the detection limit is as low as 10fM. The capability to distinguish one base-pair mismatched DNAs is also demonstrated.\",\"PeriodicalId\":6347,\"journal\":{\"name\":\"2012 Symposium on VLSI Circuits (VLSIC)\",\"volume\":\"78 2 1\",\"pages\":\"124-125\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 Symposium on VLSI Circuits (VLSIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/VLSIC.2012.6243821\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 Symposium on VLSI Circuits (VLSIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VLSIC.2012.6243821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

基于多晶硅纳米线(poly-Si NW)的生物传感器首次与无线采集电路集成在标准CMOS SoC中。为了提高检测质量,实现了一种低噪声、高CMRR、轨对轨输入范围的斩波数模模拟前端。还包括额外的温度传感器,以补偿生物传感器的温度漂移。结果表明,检测限低至10fM。还证明了区分碱基对错配dna的能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A fully integrated hepatitis B virus DNA detection SoC based on monolithic polysilicon nanowire CMOS process
Polysilicon nanowire (poly-Si NW) based biosensor is integrated with the wireless acquisition circuits in a standard CMOS SoC for the first time. To improve detection quality, a chopper DDA-based analog front-end with features of low noise, high CMRR, and rail-to-rail input range is implemented. Additional temperature sensor is also included to compensate temperature drift of the biosensor. The results indicate that the detection limit is as low as 10fM. The capability to distinguish one base-pair mismatched DNAs is also demonstrated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信