评估由单相、一步、两步和一种新的两步腻子轻体压模技术制成的铸件的尺寸精度-一项体外研究

H. Shivakumar, S. Manvi, Ulhas N Amasi, Sounyala Rayannavar
{"title":"评估由单相、一步、两步和一种新的两步腻子轻体压模技术制成的铸件的尺寸精度-一项体外研究","authors":"H. Shivakumar, S. Manvi, Ulhas N Amasi, Sounyala Rayannavar","doi":"10.4103/sjos.sjoralsci_94_19","DOIUrl":null,"url":null,"abstract":"Background: The clinical success of fixed prosthodontics and dental implants is dependent on the dimensional accuracy of the impression obtained. Although there are many studies on different impression materials and the accuracy of the dies, only a few studies on the techniques of impression making hence this study was taken to evaluate and compare the dimensional accuracy of casts made from four different impression techniques. Aim: This study aims to assess the dimensional accuracy of the resultant casts made from a monophase, one-step, two-step, and novel two-step putty light body impression technique. Settings and Design: An in vitro study. Materials and Methods: A stainless steel model of two abutments with specific distance was fabricated. An impression of this model was made with four different impression techniques using a polyvinyl siloxane impression material using custom made trays. Ten impressions were made with each impression technique. Total 40 impressions made and casts poured with type IV gypsum, and accuracy of the casts measured using a traveling microscope. Three dimensions, i.e., diameter, height, and inter-abutment distance measurements were obtained. Statistical Analysis: The statistical analysis was done using one-way ANOVA and Student Newman-Keuls test. Results and Conclusion: The casts obtained from all four techniques had significant differences in dimensions as compared to that of the master model. The order for highest to lowest accuracy from, the stainless steel model was; monophase < one-step < two-step < two-step injection technique. The two-step and two-step injection techniques produced the most accurate cast, with the two-step injection technique performance being better than the two-step technique casts obtained.","PeriodicalId":32335,"journal":{"name":"Saudi Journal of Oral Sciences","volume":"18 1","pages":"99 - 106"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Assessing the dimensional accuracy of the resultant casts made from monophase, one-step, two-step, and a novel two-step putty light body impression technique – An in vitro study\",\"authors\":\"H. Shivakumar, S. Manvi, Ulhas N Amasi, Sounyala Rayannavar\",\"doi\":\"10.4103/sjos.sjoralsci_94_19\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The clinical success of fixed prosthodontics and dental implants is dependent on the dimensional accuracy of the impression obtained. Although there are many studies on different impression materials and the accuracy of the dies, only a few studies on the techniques of impression making hence this study was taken to evaluate and compare the dimensional accuracy of casts made from four different impression techniques. Aim: This study aims to assess the dimensional accuracy of the resultant casts made from a monophase, one-step, two-step, and novel two-step putty light body impression technique. Settings and Design: An in vitro study. Materials and Methods: A stainless steel model of two abutments with specific distance was fabricated. An impression of this model was made with four different impression techniques using a polyvinyl siloxane impression material using custom made trays. Ten impressions were made with each impression technique. Total 40 impressions made and casts poured with type IV gypsum, and accuracy of the casts measured using a traveling microscope. Three dimensions, i.e., diameter, height, and inter-abutment distance measurements were obtained. Statistical Analysis: The statistical analysis was done using one-way ANOVA and Student Newman-Keuls test. Results and Conclusion: The casts obtained from all four techniques had significant differences in dimensions as compared to that of the master model. The order for highest to lowest accuracy from, the stainless steel model was; monophase < one-step < two-step < two-step injection technique. The two-step and two-step injection techniques produced the most accurate cast, with the two-step injection technique performance being better than the two-step technique casts obtained.\",\"PeriodicalId\":32335,\"journal\":{\"name\":\"Saudi Journal of Oral Sciences\",\"volume\":\"18 1\",\"pages\":\"99 - 106\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Saudi Journal of Oral Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/sjos.sjoralsci_94_19\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Journal of Oral Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/sjos.sjoralsci_94_19","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

背景:固定修复和种植体的临床成功取决于所获得的印模的尺寸精度。尽管对不同压模材料和模具精度的研究很多,但对压模制造技术的研究很少,因此本研究旨在评估和比较四种不同压模技术制造的铸件的尺寸精度。目的:本研究旨在评估由单相、一步、两步和新型两步腻子光体压模技术制成的最终铸件的尺寸精度。设置和设计:一项体外研究。材料与方法:制作具有一定距离的两个基台的不锈钢模型。这个模型的印象是用四种不同的印象技术,使用聚乙烯硅氧烷印象材料,使用定制的托盘。每种印模技术印出10个印模。总共40个印痕和浇铸用IV型石膏,铸件的精度测量使用移动显微镜。测量了三个维度,即直径、高度和基台之间的距离。统计分析:统计分析采用单因素方差分析和学生Newman-Keuls检验。结果与结论:与主模型相比,这四种方法得到的铸件在尺寸上有显著差异。从高到低的精度顺序,不锈钢模型是;单相<一步<两步<两步进样技术。两步注射工艺和两步注射工艺的铸件精度最高,两步注射工艺的铸件性能优于两步注射工艺。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessing the dimensional accuracy of the resultant casts made from monophase, one-step, two-step, and a novel two-step putty light body impression technique – An in vitro study
Background: The clinical success of fixed prosthodontics and dental implants is dependent on the dimensional accuracy of the impression obtained. Although there are many studies on different impression materials and the accuracy of the dies, only a few studies on the techniques of impression making hence this study was taken to evaluate and compare the dimensional accuracy of casts made from four different impression techniques. Aim: This study aims to assess the dimensional accuracy of the resultant casts made from a monophase, one-step, two-step, and novel two-step putty light body impression technique. Settings and Design: An in vitro study. Materials and Methods: A stainless steel model of two abutments with specific distance was fabricated. An impression of this model was made with four different impression techniques using a polyvinyl siloxane impression material using custom made trays. Ten impressions were made with each impression technique. Total 40 impressions made and casts poured with type IV gypsum, and accuracy of the casts measured using a traveling microscope. Three dimensions, i.e., diameter, height, and inter-abutment distance measurements were obtained. Statistical Analysis: The statistical analysis was done using one-way ANOVA and Student Newman-Keuls test. Results and Conclusion: The casts obtained from all four techniques had significant differences in dimensions as compared to that of the master model. The order for highest to lowest accuracy from, the stainless steel model was; monophase < one-step < two-step < two-step injection technique. The two-step and two-step injection techniques produced the most accurate cast, with the two-step injection technique performance being better than the two-step technique casts obtained.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
1
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信