{"title":"使用DVD拾取头检测单个生物细胞","authors":"S. Kostner, M. Vellekoop","doi":"10.1109/SENSOR.2007.4300585","DOIUrl":null,"url":null,"abstract":"In this paper we present an optical detection system for single biological cells that utilizes a standard DVD pickup head. In a feasibility study we have shown the detection for different plain and silver coated polystyrene particles and cells (yeast) suspended on a platinum mirror. For these experiments the integrated magnetic actor of the pickup was used to simulate the particle movement and we found a remarkable sensitivity. Then a flow cell with integrated mirror has been designed to be able to measure particles in a cytometric setup. First measurement results are given that show the high sensitivity and a good repeatability for polystyrene beads.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"224 1","pages":"2123-2126"},"PeriodicalIF":0.0000,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Detection of Single Biological Cells using a DVD Pickup Head\",\"authors\":\"S. Kostner, M. Vellekoop\",\"doi\":\"10.1109/SENSOR.2007.4300585\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper we present an optical detection system for single biological cells that utilizes a standard DVD pickup head. In a feasibility study we have shown the detection for different plain and silver coated polystyrene particles and cells (yeast) suspended on a platinum mirror. For these experiments the integrated magnetic actor of the pickup was used to simulate the particle movement and we found a remarkable sensitivity. Then a flow cell with integrated mirror has been designed to be able to measure particles in a cytometric setup. First measurement results are given that show the high sensitivity and a good repeatability for polystyrene beads.\",\"PeriodicalId\":23295,\"journal\":{\"name\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"volume\":\"224 1\",\"pages\":\"2123-2126\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2007.4300585\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2007.4300585","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Detection of Single Biological Cells using a DVD Pickup Head
In this paper we present an optical detection system for single biological cells that utilizes a standard DVD pickup head. In a feasibility study we have shown the detection for different plain and silver coated polystyrene particles and cells (yeast) suspended on a platinum mirror. For these experiments the integrated magnetic actor of the pickup was used to simulate the particle movement and we found a remarkable sensitivity. Then a flow cell with integrated mirror has been designed to be able to measure particles in a cytometric setup. First measurement results are given that show the high sensitivity and a good repeatability for polystyrene beads.