基于二羧基杯[4]芳烃的传感器(Calix/MPA/Au)差分脉冲伏安法检测镍(II)和锌(II)离子

Siti Nur Farhana Abdul Aziz, S. A. Alang Ahmad
{"title":"基于二羧基杯[4]芳烃的传感器(Calix/MPA/Au)差分脉冲伏安法检测镍(II)和锌(II)离子","authors":"Siti Nur Farhana Abdul Aziz, S. A. Alang Ahmad","doi":"10.2166/aqua.2023.179","DOIUrl":null,"url":null,"abstract":"\n Herein, we report a facile approach for constructing a calixarene-based electrochemical heavy metal sensor (Calix/MPA/Au) via a one-pot reaction for the detection of Ni(II) and Zn(II) ions. The surface elemental properties and analytical performance of the Calix/MPA/Au sensor were characterized by X-ray photoelectron spectroscopy (XPS) and differential pulse voltammetry (DPV). Under optimum conditions, the sensor exhibited detection limits of 1.5 and 0.34 mg/L at linear ranges of 2.85–6.65 and 0.13–1.68 mg/L for the Zn(II) and Ni(II) ions, respectively. The developed sensor exhibited a better electrochemical performance in the detection of Zn(II) and Ni(II) ions owing to the favourable host–guest interactions between the hydroxyl groups-functionalized lower rim of dicarboxyl-calix[4]arene and the metal ions. The RSD of the five independent Calix/MPA/Au electrode for Zn(II) and Ni(II) ions was calculated to be 16.3 and 16.1%, respectively. Despite the lower sensitivity of the modified electrode towards Ni(II) ions, this finding proves the high selectivity of the calixarene as a detection probe towards the fitted size of guest ion, hence promising to be assembled and explored as a solid-state based-supramolecular host molecule for tracing metal ions.","PeriodicalId":17666,"journal":{"name":"Journal of Water Supply: Research and Technology-Aqua","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Electrochemical detection of nickel(II) and zinc(II) ions by a dicarboxyl-Calix[4]arene-based sensor (Calix/MPA/Au) through differential pulse voltammetry analysis\",\"authors\":\"Siti Nur Farhana Abdul Aziz, S. A. Alang Ahmad\",\"doi\":\"10.2166/aqua.2023.179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n Herein, we report a facile approach for constructing a calixarene-based electrochemical heavy metal sensor (Calix/MPA/Au) via a one-pot reaction for the detection of Ni(II) and Zn(II) ions. The surface elemental properties and analytical performance of the Calix/MPA/Au sensor were characterized by X-ray photoelectron spectroscopy (XPS) and differential pulse voltammetry (DPV). Under optimum conditions, the sensor exhibited detection limits of 1.5 and 0.34 mg/L at linear ranges of 2.85–6.65 and 0.13–1.68 mg/L for the Zn(II) and Ni(II) ions, respectively. The developed sensor exhibited a better electrochemical performance in the detection of Zn(II) and Ni(II) ions owing to the favourable host–guest interactions between the hydroxyl groups-functionalized lower rim of dicarboxyl-calix[4]arene and the metal ions. The RSD of the five independent Calix/MPA/Au electrode for Zn(II) and Ni(II) ions was calculated to be 16.3 and 16.1%, respectively. Despite the lower sensitivity of the modified electrode towards Ni(II) ions, this finding proves the high selectivity of the calixarene as a detection probe towards the fitted size of guest ion, hence promising to be assembled and explored as a solid-state based-supramolecular host molecule for tracing metal ions.\",\"PeriodicalId\":17666,\"journal\":{\"name\":\"Journal of Water Supply: Research and Technology-Aqua\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Water Supply: Research and Technology-Aqua\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2166/aqua.2023.179\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Water Supply: Research and Technology-Aqua","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2166/aqua.2023.179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文报道了一种简单的方法,通过一锅反应构建基于杯芳烃的电化学重金属传感器(Calix/MPA/Au),用于检测Ni(II)和Zn(II)离子。采用x射线光电子能谱(XPS)和差分脉冲伏安法(DPV)对Calix/MPA/Au传感器的表面元素性质和分析性能进行了表征。在最佳条件下,该传感器在2.85 ~ 6.65和0.13 ~ 1.68 mg/L线性范围内对Zn(II)和Ni(II)离子的检出限分别为1.5和0.34 mg/L。该传感器在检测Zn(II)和Ni(II)离子时表现出较好的电化学性能,这是由于二羧基杯芳烃下缘羟基与金属离子之间良好的主客体相互作用。计算出5种独立的Calix/MPA/Au电极对Zn(II)和Ni(II)离子的RSD分别为16.3%和16.1%。尽管修饰电极对Ni(II)离子的灵敏度较低,但这一发现证明了杯芳烃作为探测探针对合适尺寸的客体离子具有很高的选择性,因此有望作为固体基超分子宿主分子进行组装和探索,用于追踪金属离子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrochemical detection of nickel(II) and zinc(II) ions by a dicarboxyl-Calix[4]arene-based sensor (Calix/MPA/Au) through differential pulse voltammetry analysis
Herein, we report a facile approach for constructing a calixarene-based electrochemical heavy metal sensor (Calix/MPA/Au) via a one-pot reaction for the detection of Ni(II) and Zn(II) ions. The surface elemental properties and analytical performance of the Calix/MPA/Au sensor were characterized by X-ray photoelectron spectroscopy (XPS) and differential pulse voltammetry (DPV). Under optimum conditions, the sensor exhibited detection limits of 1.5 and 0.34 mg/L at linear ranges of 2.85–6.65 and 0.13–1.68 mg/L for the Zn(II) and Ni(II) ions, respectively. The developed sensor exhibited a better electrochemical performance in the detection of Zn(II) and Ni(II) ions owing to the favourable host–guest interactions between the hydroxyl groups-functionalized lower rim of dicarboxyl-calix[4]arene and the metal ions. The RSD of the five independent Calix/MPA/Au electrode for Zn(II) and Ni(II) ions was calculated to be 16.3 and 16.1%, respectively. Despite the lower sensitivity of the modified electrode towards Ni(II) ions, this finding proves the high selectivity of the calixarene as a detection probe towards the fitted size of guest ion, hence promising to be assembled and explored as a solid-state based-supramolecular host molecule for tracing metal ions.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信