Preliminary基于电流评价的铁路架空线动物导流器护鸟效果研究

IF 1.2 Q3 BIODIVERSITY CONSERVATION
S. Kornhuber, H.-P. Pampel, J. Görlich, Marion Leiblein-Wild, Christoph Jöckle
{"title":"Preliminary基于电流评价的铁路架空线动物导流器护鸟效果研究","authors":"S. Kornhuber, H.-P. Pampel, J. Görlich, Marion Leiblein-Wild, Christoph Jöckle","doi":"10.3897/natureconservation.47.70704","DOIUrl":null,"url":null,"abstract":"In contrast to other transportation systems, railway systems feature special characteristics, which may cause specific hazards to birds. Among other things, there is the risk of electrocutions resulting from short circuits. To protect the birds and minimize these short circuit events, the DB Netz AG has installed so-called animal deflectors on the insulators of the overhead lines. Since this effort, the number of short-circuit events in the respective sections has decreased, according to DB Netz AG. The principal mechanism of action of the animal deflectors is based on mechanical defense, combined with electrostatic discharge on contact. Although the number of short circuit events has been reduced by using animal deflectors, the detailed function of the animal deflector in different environmental conditions has not been investigated up to now. This research project aims to determine whether, and to what extent, the use of animal deflectors in retrofitting overhead lines may contribute to bird protection and which currents can be measured at retrofitted insulators under different environmental conditions. Hence the current should be measured when using animal deflectors on railway overhead lines for different isolator states and body resistances (5 kΩ, 3 kΩ, 1kΩ, 0.5 kΩ). The results show an influence of measured current depending on the insulator state. Our preliminary results indicate that the use of an animal deflector (KTA) to the tested polymeric insulator and pollution severity can be recommended, since, based on the investigations, no danger to small birds and small animals can be identified. However, the use of the animal deflector (KTA) for the tested porcelain insulator and pollution severity should not be recommended as they showed high animal hazards during pollution and fog conditions. However, these results cannot be transferred to other different insulator types and pollution severities. Investigating the electrical current to the type of insulator used and the expected pollution severity is recommended.","PeriodicalId":54166,"journal":{"name":"Nature Conservation Research","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2022-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Preliminary results on the bird protection effectiveness of animal deflectors on railway overhead lines based on electrical current evaluation\",\"authors\":\"S. Kornhuber, H.-P. Pampel, J. Görlich, Marion Leiblein-Wild, Christoph Jöckle\",\"doi\":\"10.3897/natureconservation.47.70704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In contrast to other transportation systems, railway systems feature special characteristics, which may cause specific hazards to birds. Among other things, there is the risk of electrocutions resulting from short circuits. To protect the birds and minimize these short circuit events, the DB Netz AG has installed so-called animal deflectors on the insulators of the overhead lines. Since this effort, the number of short-circuit events in the respective sections has decreased, according to DB Netz AG. The principal mechanism of action of the animal deflectors is based on mechanical defense, combined with electrostatic discharge on contact. Although the number of short circuit events has been reduced by using animal deflectors, the detailed function of the animal deflector in different environmental conditions has not been investigated up to now. This research project aims to determine whether, and to what extent, the use of animal deflectors in retrofitting overhead lines may contribute to bird protection and which currents can be measured at retrofitted insulators under different environmental conditions. Hence the current should be measured when using animal deflectors on railway overhead lines for different isolator states and body resistances (5 kΩ, 3 kΩ, 1kΩ, 0.5 kΩ). The results show an influence of measured current depending on the insulator state. Our preliminary results indicate that the use of an animal deflector (KTA) to the tested polymeric insulator and pollution severity can be recommended, since, based on the investigations, no danger to small birds and small animals can be identified. However, the use of the animal deflector (KTA) for the tested porcelain insulator and pollution severity should not be recommended as they showed high animal hazards during pollution and fog conditions. However, these results cannot be transferred to other different insulator types and pollution severities. Investigating the electrical current to the type of insulator used and the expected pollution severity is recommended.\",\"PeriodicalId\":54166,\"journal\":{\"name\":\"Nature Conservation Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2022-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nature Conservation Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3897/natureconservation.47.70704\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"BIODIVERSITY CONSERVATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nature Conservation Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3897/natureconservation.47.70704","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIODIVERSITY CONSERVATION","Score":null,"Total":0}
引用次数: 1

摘要

与其他运输系统相比,铁路系统具有特殊的特性,可能会对鸟类造成特定的危害。除此之外,还有因短路而触电的危险。为了保护鸟类并尽量减少这些短路事件,DB Netz AG在架空线路的绝缘体上安装了所谓的动物偏转器。根据DB Netz AG的数据,由于这一努力,相应路段的短路事件数量有所减少。动物导流器的主要作用机理是以机械防御为基础,结合接触时的静电放电。虽然动物导流器的使用减少了短路事件的发生,但目前还没有研究动物导流器在不同环境条件下的具体作用。该研究项目旨在确定在改造架空线路时使用动物偏转管是否以及在多大程度上有助于保护鸟类,以及在不同环境条件下,在改造后的绝缘子上可以测量哪些电流。因此,在铁路架空线上使用动物偏转器时,应测量不同隔离器状态和体电阻(5 kΩ, 3 kΩ, 1kΩ, 0.5 kΩ)的电流。结果表明,测量电流随绝缘子状态的变化而变化。我们的初步结果表明,可以推荐对测试的聚合物绝缘体使用动物偏转器(KTA)和污染严重程度,因为根据调查,可以确定对小鸟和小动物没有危险。然而,不建议使用动物偏转器(KTA)测试瓷绝缘体和污染严重程度,因为它们在污染和雾条件下显示出很高的动物危害。然而,这些结果不能转移到其他不同类型的绝缘子和污染严重程度。调查所使用的绝缘体类型的电流和预期的污染严重程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Preliminary results on the bird protection effectiveness of animal deflectors on railway overhead lines based on electrical current evaluation
In contrast to other transportation systems, railway systems feature special characteristics, which may cause specific hazards to birds. Among other things, there is the risk of electrocutions resulting from short circuits. To protect the birds and minimize these short circuit events, the DB Netz AG has installed so-called animal deflectors on the insulators of the overhead lines. Since this effort, the number of short-circuit events in the respective sections has decreased, according to DB Netz AG. The principal mechanism of action of the animal deflectors is based on mechanical defense, combined with electrostatic discharge on contact. Although the number of short circuit events has been reduced by using animal deflectors, the detailed function of the animal deflector in different environmental conditions has not been investigated up to now. This research project aims to determine whether, and to what extent, the use of animal deflectors in retrofitting overhead lines may contribute to bird protection and which currents can be measured at retrofitted insulators under different environmental conditions. Hence the current should be measured when using animal deflectors on railway overhead lines for different isolator states and body resistances (5 kΩ, 3 kΩ, 1kΩ, 0.5 kΩ). The results show an influence of measured current depending on the insulator state. Our preliminary results indicate that the use of an animal deflector (KTA) to the tested polymeric insulator and pollution severity can be recommended, since, based on the investigations, no danger to small birds and small animals can be identified. However, the use of the animal deflector (KTA) for the tested porcelain insulator and pollution severity should not be recommended as they showed high animal hazards during pollution and fog conditions. However, these results cannot be transferred to other different insulator types and pollution severities. Investigating the electrical current to the type of insulator used and the expected pollution severity is recommended.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nature Conservation Research
Nature Conservation Research BIODIVERSITY CONSERVATION-
CiteScore
4.70
自引率
5.90%
发文量
34
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信