Jawaria Ahad, Amjad Farooq, Masroor Ahmad, K. Waheed, K. Qureshi, Waseem Siddique, N. Irfan
{"title":"浸没式文丘里洗涤器除碘实验研究","authors":"Jawaria Ahad, Amjad Farooq, Masroor Ahmad, K. Waheed, K. Qureshi, Waseem Siddique, N. Irfan","doi":"10.3390/engproc2021012038","DOIUrl":null,"url":null,"abstract":"Severe nuclear accidents can cause over-pressurization and serious damage to the containment of a nuclear power plant, which can result in the release of radioactivity into the environment. Filtered containment venting systems are a nuclear safety system that is designed to control over-pressurization and prevent radioactive fission products from spreading into the environment in the case of a severe accident. Iodine is one of the most harmful products among this list of fissionable products, as it can cause thyroid cancer. The removal of iodine is very important in order to ensure the safety of people and the environment. Thus, an indigenous lab scale setup of this system was developed at PIEAS to conduct research on iodine removal. It is comprised of a compressor for replicating high-pressure accident scenarios, a heater to keep iodine in a vapor form, a dosing pump for the injection of iodine, and a venturi scrubber, submerged in the scrubbing column, containing a solution of 0.2% sodium thiosulphate and 0.5% sodium hydroxide. Inlet and outlet samples were trapped in 0.1 M KOH solution and analyzed via UV-VIS spectroscopy. Operating parameters play an important role in the working of a venturi scrubber. The throat velocity was varied to determine its influence on the removal efficiency of iodine. An increase in removal efficiency was observed with an increase in throat velocity. A removal efficiency of >99% was achieved, which fulfilled the requirements for FCVS.","PeriodicalId":11748,"journal":{"name":"Engineering Proceedings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Experimental Investigation of Iodine Removal in a Submerged Venturi Scrubber\",\"authors\":\"Jawaria Ahad, Amjad Farooq, Masroor Ahmad, K. Waheed, K. Qureshi, Waseem Siddique, N. Irfan\",\"doi\":\"10.3390/engproc2021012038\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Severe nuclear accidents can cause over-pressurization and serious damage to the containment of a nuclear power plant, which can result in the release of radioactivity into the environment. Filtered containment venting systems are a nuclear safety system that is designed to control over-pressurization and prevent radioactive fission products from spreading into the environment in the case of a severe accident. Iodine is one of the most harmful products among this list of fissionable products, as it can cause thyroid cancer. The removal of iodine is very important in order to ensure the safety of people and the environment. Thus, an indigenous lab scale setup of this system was developed at PIEAS to conduct research on iodine removal. It is comprised of a compressor for replicating high-pressure accident scenarios, a heater to keep iodine in a vapor form, a dosing pump for the injection of iodine, and a venturi scrubber, submerged in the scrubbing column, containing a solution of 0.2% sodium thiosulphate and 0.5% sodium hydroxide. Inlet and outlet samples were trapped in 0.1 M KOH solution and analyzed via UV-VIS spectroscopy. Operating parameters play an important role in the working of a venturi scrubber. The throat velocity was varied to determine its influence on the removal efficiency of iodine. An increase in removal efficiency was observed with an increase in throat velocity. A removal efficiency of >99% was achieved, which fulfilled the requirements for FCVS.\",\"PeriodicalId\":11748,\"journal\":{\"name\":\"Engineering Proceedings\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Engineering Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/engproc2021012038\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/engproc2021012038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
摘要
严重的核事故会导致核电站的压力过大,并严重损坏核电站的安全壳,从而导致放射性物质释放到环境中。过滤式安全壳排气系统是一种核安全系统,用于在发生严重事故时控制过压,防止放射性裂变产物扩散到环境中。碘是这些裂变产物中最有害的产物之一,因为它会导致甲状腺癌。除碘对于保证人体和环境的安全至关重要。因此,在PIEAS开发了该系统的本土实验室规模设置,以进行除碘研究。它包括一个用于模拟高压事故场景的压缩机、一个用于将碘保持在蒸汽状态的加热器、一个用于注射碘的加药泵和一个文丘里洗涤器,文丘里洗涤器浸没在洗涤塔中,含有0.2%硫硫酸钠和0.5%氢氧化钠的溶液。进出口样品用0.1 M KOH溶液捕获,紫外-可见光谱分析。运行参数对文丘里洗涤器的工作起着重要的作用。研究了不同喉道流速对碘去除率的影响。随着喉部速度的增加,去除效率也随之增加。结果表明,该工艺的去除率达到了99%,达到了燃料电池电池的要求。
Experimental Investigation of Iodine Removal in a Submerged Venturi Scrubber
Severe nuclear accidents can cause over-pressurization and serious damage to the containment of a nuclear power plant, which can result in the release of radioactivity into the environment. Filtered containment venting systems are a nuclear safety system that is designed to control over-pressurization and prevent radioactive fission products from spreading into the environment in the case of a severe accident. Iodine is one of the most harmful products among this list of fissionable products, as it can cause thyroid cancer. The removal of iodine is very important in order to ensure the safety of people and the environment. Thus, an indigenous lab scale setup of this system was developed at PIEAS to conduct research on iodine removal. It is comprised of a compressor for replicating high-pressure accident scenarios, a heater to keep iodine in a vapor form, a dosing pump for the injection of iodine, and a venturi scrubber, submerged in the scrubbing column, containing a solution of 0.2% sodium thiosulphate and 0.5% sodium hydroxide. Inlet and outlet samples were trapped in 0.1 M KOH solution and analyzed via UV-VIS spectroscopy. Operating parameters play an important role in the working of a venturi scrubber. The throat velocity was varied to determine its influence on the removal efficiency of iodine. An increase in removal efficiency was observed with an increase in throat velocity. A removal efficiency of >99% was achieved, which fulfilled the requirements for FCVS.