尼日利亚卡诺州制革工业废水中固定化细菌的阴离子生物修复潜力

IF 1.4 3区 管理学 Q2 INFORMATION SCIENCE & LIBRARY SCIENCE
A. Baba, S. Garba, H. Abdullahi, D. Baba
{"title":"尼日利亚卡诺州制革工业废水中固定化细菌的阴离子生物修复潜力","authors":"A. Baba, S. Garba, H. Abdullahi, D. Baba","doi":"10.22034/CRL.2020.244405.1078","DOIUrl":null,"url":null,"abstract":"The present study aims to assess the potentials of immobilized bacteria in the remediation of anions within the effluents by determining the levels of the anions before and after the remediation. Industrial Effluents Samples from Gashash Tanneries (TAN1), Larabee Tannery Industry (TAN2) and Z Tannery Industries (TAN3) in Kano State, Nigeria were collected monthly for six months (August 2017 to January 2018). Bacteria were isolated from the effluents and immobilized on agar-agar. The effluent samples were analyzed for the anions before and after the treatment using DR/2010 HACH portable data logging spectrophotometer. Different masses (5 g, 10 g, 15 g, 20 g, and 25 g) of the bacteria were used in the treatment of 250 ml of the effluents for ten days in a shaker incubator (Gallenkamp-OC-4364-L) at the temperature 30 °C and speed of 60 rpm. Pre-treatment analysis of the effluents for nitrate (NO-3), Sulphate (SO2-4), Phosphate (PO3-4) and Chloride (Cl-) give the following results; NO-3 ranged (25.35±17.16-28.12±10.72 mg/l); SO2-4 (67.00±5.93-114.83±53.20 mg/l); PO3-4 (26.16±22.93-34.17±16.73 mg/l) and Cl- (22.57±9.64-26.00a±4.86 mg/l). No statistical difference (p ≤ 0.05) was observed for all the anions among the different industries. The bacterial isolates were identified as Neisseria spp, Bacillus cereus, and Staphylococcus aureus, in TAN1, TAN2, and TAN3, respectively. After treatment of the effluents with the different masses of the isolated bacteria, the mean level of NO-3 were found to range as (6.17±6.67-20.78±7.76); SO2-4 (25.73±17.84-46.00±46.81); PO3-4 (11.45±12.02-28.19±9.09) and Cl-(0.38±1.83-15.36±13.58). The results of Post-treatment analysis showed that there is an overall decrease in the levels of the anions determined when compared with that of the pre-treatment. The overall percentage reduction of the immobilized bacteria in the treatment of the respective effluents was in the order TAN3 (57%)>TAN1 (49%)>TAN2 (47%). Therefore, the immobilized bacteria are having higher potentials for the treatment of the anions in the effluents.","PeriodicalId":10686,"journal":{"name":"College & Research Libraries","volume":"419 1","pages":"43-53"},"PeriodicalIF":1.4000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Anions Bioremediation Potential of Immobilized Bacteria in Tannery Industrial Effluents from Kano State, Nigeria\",\"authors\":\"A. Baba, S. Garba, H. Abdullahi, D. Baba\",\"doi\":\"10.22034/CRL.2020.244405.1078\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present study aims to assess the potentials of immobilized bacteria in the remediation of anions within the effluents by determining the levels of the anions before and after the remediation. Industrial Effluents Samples from Gashash Tanneries (TAN1), Larabee Tannery Industry (TAN2) and Z Tannery Industries (TAN3) in Kano State, Nigeria were collected monthly for six months (August 2017 to January 2018). Bacteria were isolated from the effluents and immobilized on agar-agar. The effluent samples were analyzed for the anions before and after the treatment using DR/2010 HACH portable data logging spectrophotometer. Different masses (5 g, 10 g, 15 g, 20 g, and 25 g) of the bacteria were used in the treatment of 250 ml of the effluents for ten days in a shaker incubator (Gallenkamp-OC-4364-L) at the temperature 30 °C and speed of 60 rpm. Pre-treatment analysis of the effluents for nitrate (NO-3), Sulphate (SO2-4), Phosphate (PO3-4) and Chloride (Cl-) give the following results; NO-3 ranged (25.35±17.16-28.12±10.72 mg/l); SO2-4 (67.00±5.93-114.83±53.20 mg/l); PO3-4 (26.16±22.93-34.17±16.73 mg/l) and Cl- (22.57±9.64-26.00a±4.86 mg/l). No statistical difference (p ≤ 0.05) was observed for all the anions among the different industries. The bacterial isolates were identified as Neisseria spp, Bacillus cereus, and Staphylococcus aureus, in TAN1, TAN2, and TAN3, respectively. After treatment of the effluents with the different masses of the isolated bacteria, the mean level of NO-3 were found to range as (6.17±6.67-20.78±7.76); SO2-4 (25.73±17.84-46.00±46.81); PO3-4 (11.45±12.02-28.19±9.09) and Cl-(0.38±1.83-15.36±13.58). The results of Post-treatment analysis showed that there is an overall decrease in the levels of the anions determined when compared with that of the pre-treatment. The overall percentage reduction of the immobilized bacteria in the treatment of the respective effluents was in the order TAN3 (57%)>TAN1 (49%)>TAN2 (47%). Therefore, the immobilized bacteria are having higher potentials for the treatment of the anions in the effluents.\",\"PeriodicalId\":10686,\"journal\":{\"name\":\"College & Research Libraries\",\"volume\":\"419 1\",\"pages\":\"43-53\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"College & Research Libraries\",\"FirstCategoryId\":\"91\",\"ListUrlMain\":\"https://doi.org/10.22034/CRL.2020.244405.1078\",\"RegionNum\":3,\"RegionCategory\":\"管理学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INFORMATION SCIENCE & LIBRARY SCIENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"College & Research Libraries","FirstCategoryId":"91","ListUrlMain":"https://doi.org/10.22034/CRL.2020.244405.1078","RegionNum":3,"RegionCategory":"管理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INFORMATION SCIENCE & LIBRARY SCIENCE","Score":null,"Total":0}
引用次数: 3

摘要

本研究旨在通过测定污水中阴离子修复前后的水平,评估固定化细菌在污水中阴离子修复中的潜力。每月收集尼日利亚卡诺州Gashash制革厂(TAN1)、Larabee制革厂(TAN2)和Z制革厂(TAN3)的工业废水样本,为期六个月(2017年8月至2018年1月)。从废水中分离出细菌并将其固定在琼脂上。采用DR/2010 HACH便携式数据记录仪对处理前后的出水样品进行阴离子分析。取不同质量(5 g、10 g、15 g、20 g、25 g)的细菌,在摇床培养箱(Gallenkamp-OC-4364-L)中,温度30℃,转速60 rpm,处理250 ml废水10天。对废水中硝酸盐(NO-3)、硫酸盐(SO2-4)、磷酸盐(PO3-4)和氯化物(Cl-)的预处理分析结果如下:NO-3为25.35±17.16-28.12±10.72 mg/l;硫酸(67.00±5.93 ~ 114.83±53.20 mg/l);PO3-4(26.16±22.93 -34.17±16.73 mg / l)和Cl - -26.00(22.57±9.64±4.86 mg / l)。不同行业间阴离子含量差异无统计学意义(p≤0.05)。在TAN1、TAN2和TAN3中分别分离出奈瑟氏菌、蜡样芽孢杆菌和金黄色葡萄球菌。用不同质量的分离菌处理出水后,NO-3的平均水平为(6.17±6.67 ~ 20.78±7.76);共同作用(25.73±17.84 -46.00±46.81);PO3-4(11.45±12.02 -28.19±9.09)和Cl -(0.38±1.83 - -15.36±13.58)。处理后的分析结果表明,与预处理相比,阴离子的测定水平总体上有所下降。固定化菌在各废水处理中的总体降幅为:TAN3 (57%)>TAN1 (49%)>TAN2(47%)。因此,固定化细菌对废水中的阴离子具有较高的处理潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Anions Bioremediation Potential of Immobilized Bacteria in Tannery Industrial Effluents from Kano State, Nigeria
The present study aims to assess the potentials of immobilized bacteria in the remediation of anions within the effluents by determining the levels of the anions before and after the remediation. Industrial Effluents Samples from Gashash Tanneries (TAN1), Larabee Tannery Industry (TAN2) and Z Tannery Industries (TAN3) in Kano State, Nigeria were collected monthly for six months (August 2017 to January 2018). Bacteria were isolated from the effluents and immobilized on agar-agar. The effluent samples were analyzed for the anions before and after the treatment using DR/2010 HACH portable data logging spectrophotometer. Different masses (5 g, 10 g, 15 g, 20 g, and 25 g) of the bacteria were used in the treatment of 250 ml of the effluents for ten days in a shaker incubator (Gallenkamp-OC-4364-L) at the temperature 30 °C and speed of 60 rpm. Pre-treatment analysis of the effluents for nitrate (NO-3), Sulphate (SO2-4), Phosphate (PO3-4) and Chloride (Cl-) give the following results; NO-3 ranged (25.35±17.16-28.12±10.72 mg/l); SO2-4 (67.00±5.93-114.83±53.20 mg/l); PO3-4 (26.16±22.93-34.17±16.73 mg/l) and Cl- (22.57±9.64-26.00a±4.86 mg/l). No statistical difference (p ≤ 0.05) was observed for all the anions among the different industries. The bacterial isolates were identified as Neisseria spp, Bacillus cereus, and Staphylococcus aureus, in TAN1, TAN2, and TAN3, respectively. After treatment of the effluents with the different masses of the isolated bacteria, the mean level of NO-3 were found to range as (6.17±6.67-20.78±7.76); SO2-4 (25.73±17.84-46.00±46.81); PO3-4 (11.45±12.02-28.19±9.09) and Cl-(0.38±1.83-15.36±13.58). The results of Post-treatment analysis showed that there is an overall decrease in the levels of the anions determined when compared with that of the pre-treatment. The overall percentage reduction of the immobilized bacteria in the treatment of the respective effluents was in the order TAN3 (57%)>TAN1 (49%)>TAN2 (47%). Therefore, the immobilized bacteria are having higher potentials for the treatment of the anions in the effluents.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
College & Research Libraries
College & Research Libraries INFORMATION SCIENCE & LIBRARY SCIENCE-
CiteScore
3.10
自引率
22.20%
发文量
63
审稿时长
45 weeks
期刊介绍: College & Research Libraries (C&RL) is the official scholarly research journal of the Association of College & Research Libraries, a division of the American Library Association, 50 East Huron St., Chicago, IL 60611. C&RL is a bimonthly, online-only publication highlighting a new C&RL study with a free, live, expert panel comprised of the study''s authors and additional subject experts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信