{"title":"干涉仪传递函数测试方法","authors":"孙鸽 Sun Ge, 马冬梅 Ma Dongmei, 张海涛 Zhang Hai-tao","doi":"10.3788/CO.20140701.0137","DOIUrl":null,"url":null,"abstract":"To acquire the spatial frequency response of the interferometer,the testing method on instrument transfer function( ITF) of interferometer was researched. First,the theoretical calculation model of instrument transfer function of imaging system was established,and the testing model of Fizeau interferometer was simulated via lens design program. Then the theoretical value was calculated and anaysed. Comparing ITF based on the method of sine phase plate with the theoretical ITF,the error is less than 0. 6%,and this method is proved to be feasible via the simulation of the optical design program.","PeriodicalId":10133,"journal":{"name":"Chinese Journal of Optics and Applied Optics","volume":"70 1","pages":"137-143"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Interferometer instrument transfer function testing method\",\"authors\":\"孙鸽 Sun Ge, 马冬梅 Ma Dongmei, 张海涛 Zhang Hai-tao\",\"doi\":\"10.3788/CO.20140701.0137\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To acquire the spatial frequency response of the interferometer,the testing method on instrument transfer function( ITF) of interferometer was researched. First,the theoretical calculation model of instrument transfer function of imaging system was established,and the testing model of Fizeau interferometer was simulated via lens design program. Then the theoretical value was calculated and anaysed. Comparing ITF based on the method of sine phase plate with the theoretical ITF,the error is less than 0. 6%,and this method is proved to be feasible via the simulation of the optical design program.\",\"PeriodicalId\":10133,\"journal\":{\"name\":\"Chinese Journal of Optics and Applied Optics\",\"volume\":\"70 1\",\"pages\":\"137-143\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chinese Journal of Optics and Applied Optics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3788/CO.20140701.0137\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Optics and Applied Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3788/CO.20140701.0137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Interferometer instrument transfer function testing method
To acquire the spatial frequency response of the interferometer,the testing method on instrument transfer function( ITF) of interferometer was researched. First,the theoretical calculation model of instrument transfer function of imaging system was established,and the testing model of Fizeau interferometer was simulated via lens design program. Then the theoretical value was calculated and anaysed. Comparing ITF based on the method of sine phase plate with the theoretical ITF,the error is less than 0. 6%,and this method is proved to be feasible via the simulation of the optical design program.