{"title":"基于物联网ESP32的家庭用电保护与监控自动化设计","authors":"Habib Satria, Mangara Mual Gunawan Lubis, S. Muthia Putri","doi":"10.25077/aijaset.v2i03.53","DOIUrl":null,"url":null,"abstract":"existence of a household electrical protection and monitoring system to minimize danger. Therefore, a prototype design tool for household electricity protection and monitoring automation with IoT ESP 32 is developed. With the aim of carrying out voltage protection and electricity monitoring with a normal voltage of 220 VAC. designed to increase the existing protection system in the household, not to replace the function of the MCB. With a success rate of 99.6% voltage measurement, 97.5% current and 97.8% power measurement. Testing the tool using an inductive load in the form of a 45 watt 35, watt, 26 watt LED lamp and a resistive load in the form of a 400 watt iron set at the maximum hot point. below 210 VAC.","PeriodicalId":7884,"journal":{"name":"Andalasian International Journal of Applied Science, Engineering and Technology","volume":"32 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design of Household Electricity Protection and Monitoring Automation With IoT ESP32\",\"authors\":\"Habib Satria, Mangara Mual Gunawan Lubis, S. Muthia Putri\",\"doi\":\"10.25077/aijaset.v2i03.53\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"existence of a household electrical protection and monitoring system to minimize danger. Therefore, a prototype design tool for household electricity protection and monitoring automation with IoT ESP 32 is developed. With the aim of carrying out voltage protection and electricity monitoring with a normal voltage of 220 VAC. designed to increase the existing protection system in the household, not to replace the function of the MCB. With a success rate of 99.6% voltage measurement, 97.5% current and 97.8% power measurement. Testing the tool using an inductive load in the form of a 45 watt 35, watt, 26 watt LED lamp and a resistive load in the form of a 400 watt iron set at the maximum hot point. below 210 VAC.\",\"PeriodicalId\":7884,\"journal\":{\"name\":\"Andalasian International Journal of Applied Science, Engineering and Technology\",\"volume\":\"32 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Andalasian International Journal of Applied Science, Engineering and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25077/aijaset.v2i03.53\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Andalasian International Journal of Applied Science, Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25077/aijaset.v2i03.53","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

存在家用电气保护和监控系统,以尽量减少危险。为此,开发了一种基于IoT ESP 32的家庭用电保护与监控自动化的原型设计工具。目的是在正常电压为220伏的情况下进行电压保护和电力监测。旨在增加家庭现有的保护系统,而不是取代MCB的功能。电压测量成功率为99.6%,电流测量成功率为97.5%,功率测量成功率为97.8%。使用45瓦、35瓦、26瓦LED灯形式的感应负载和400瓦熨斗形式的电阻负载在最大热点处测试工具。低于210 VAC。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Design of Household Electricity Protection and Monitoring Automation With IoT ESP32
existence of a household electrical protection and monitoring system to minimize danger. Therefore, a prototype design tool for household electricity protection and monitoring automation with IoT ESP 32 is developed. With the aim of carrying out voltage protection and electricity monitoring with a normal voltage of 220 VAC. designed to increase the existing protection system in the household, not to replace the function of the MCB. With a success rate of 99.6% voltage measurement, 97.5% current and 97.8% power measurement. Testing the tool using an inductive load in the form of a 45 watt 35, watt, 26 watt LED lamp and a resistive load in the form of a 400 watt iron set at the maximum hot point. below 210 VAC.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信