{"title":"便携式特高压零值绝缘子检测装置的设计与应用研究","authors":"Xueming Zhou, Danhui Hu, Zijian Li, Zhiqiang Feng, Yaodong Zhang, Tianru Shi","doi":"10.1109/AEERO52475.2021.9708194","DOIUrl":null,"url":null,"abstract":"The regulations require that when installing UHV porcelain insulators, the insulation resistance should be measured with an insulation resistance meter no less than 5000V, and the resistance value of the insulator should be no less than 500M $\\Omega$ under dry conditions. Traditional insulator zero detection methods include insulation resistance meter, simple pulse device, spark fork method and voltage distribution method. Due to the above methods, the test voltage is too low, the device is bulky, the operation is complicated, or the accuracy is greatly affected by the external environment, resulting in unsatisfactory application effects. For this reason, this article mainly studies a portable insulator zero value test device, and meets the following technical requirements: output voltage above 60kV, deviation less than 5% test range 0 $\\sim$ 5000M $\\Omega$, resolution: 1M $\\Omega$, error no more than 10 % weight no more than 3kg; The number of continuous use of a single charge of the power supply is not less than 5000 times. The device is small and portable, with high accuracy, which is able to detect the insulators one by one without dismantling the wooden crates.","PeriodicalId":6828,"journal":{"name":"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)","volume":"40 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on Design and Application of Portable UHV Zero Value Insulator Detection Device\",\"authors\":\"Xueming Zhou, Danhui Hu, Zijian Li, Zhiqiang Feng, Yaodong Zhang, Tianru Shi\",\"doi\":\"10.1109/AEERO52475.2021.9708194\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The regulations require that when installing UHV porcelain insulators, the insulation resistance should be measured with an insulation resistance meter no less than 5000V, and the resistance value of the insulator should be no less than 500M $\\\\Omega$ under dry conditions. Traditional insulator zero detection methods include insulation resistance meter, simple pulse device, spark fork method and voltage distribution method. Due to the above methods, the test voltage is too low, the device is bulky, the operation is complicated, or the accuracy is greatly affected by the external environment, resulting in unsatisfactory application effects. For this reason, this article mainly studies a portable insulator zero value test device, and meets the following technical requirements: output voltage above 60kV, deviation less than 5% test range 0 $\\\\sim$ 5000M $\\\\Omega$, resolution: 1M $\\\\Omega$, error no more than 10 % weight no more than 3kg; The number of continuous use of a single charge of the power supply is not less than 5000 times. The device is small and portable, with high accuracy, which is able to detect the insulators one by one without dismantling the wooden crates.\",\"PeriodicalId\":6828,\"journal\":{\"name\":\"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)\",\"volume\":\"40 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEERO52475.2021.9708194\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEERO52475.2021.9708194","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
规定要求在安装特高压瓷绝缘子时,应用绝缘电阻计测量绝缘电阻不小于5000V,干燥条件下绝缘子的电阻值应不小于500M $\Omega$。传统的绝缘子零位检测方法包括绝缘电阻计、简易脉冲装置、火花叉法和电压分配法。由于以上方法,测试电压过低,设备体积庞大,操作复杂,或精度受外界环境影响较大,导致应用效果不理想。为此,本文主要研究一种便携式绝缘子零值试验装置,其技术要求为:输出电压60kV以上,偏差小于5% test range 0 $\sim$ 5000M $\Omega$, resolution: 1M $\Omega$, error no more than 10 % weight no more than 3kg; The number of continuous use of a single charge of the power supply is not less than 5000 times. The device is small and portable, with high accuracy, which is able to detect the insulators one by one without dismantling the wooden crates.
Research on Design and Application of Portable UHV Zero Value Insulator Detection Device
The regulations require that when installing UHV porcelain insulators, the insulation resistance should be measured with an insulation resistance meter no less than 5000V, and the resistance value of the insulator should be no less than 500M $\Omega$ under dry conditions. Traditional insulator zero detection methods include insulation resistance meter, simple pulse device, spark fork method and voltage distribution method. Due to the above methods, the test voltage is too low, the device is bulky, the operation is complicated, or the accuracy is greatly affected by the external environment, resulting in unsatisfactory application effects. For this reason, this article mainly studies a portable insulator zero value test device, and meets the following technical requirements: output voltage above 60kV, deviation less than 5% test range 0 $\sim$ 5000M $\Omega$, resolution: 1M $\Omega$, error no more than 10 % weight no more than 3kg; The number of continuous use of a single charge of the power supply is not less than 5000 times. The device is small and portable, with high accuracy, which is able to detect the insulators one by one without dismantling the wooden crates.