I. Krakhmalin, A. Chivenkov, Y. Vagapov, A. Anuchin
{"title":"用直流输电和分绕组电力变压器减少短路电流","authors":"I. Krakhmalin, A. Chivenkov, Y. Vagapov, A. Anuchin","doi":"10.1109/UPEC.2019.8893544","DOIUrl":null,"url":null,"abstract":"This paper discusses a new scheme to reduce the level of fault currents in the feeder cable and power transformer windings under short-circuit conditions. The proposed scheme suggests splitting the feeder cable in two cables and connecting it to a network through two rectifier units. Therefore, the split windings of the power transformer are supplied by a six-conductor feeder using unidirectional dc current. Unidirectional magnetic flux produced by the windings are summarised in the transformer core resulting ac flux to ensure a normal transformer operation. The proposed scheme was analysed under short and open-circuit faults. It has been shown that the short-circuit currents in the cable conductors and transformer windings are reduced in 1.41 times in comparison to a conventional scheme.","PeriodicalId":6670,"journal":{"name":"2019 54th International Universities Power Engineering Conference (UPEC)","volume":"298 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2019-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Reduction of Short Circuit Current using DC Transmission and Split-Winding Power Transformer\",\"authors\":\"I. Krakhmalin, A. Chivenkov, Y. Vagapov, A. Anuchin\",\"doi\":\"10.1109/UPEC.2019.8893544\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper discusses a new scheme to reduce the level of fault currents in the feeder cable and power transformer windings under short-circuit conditions. The proposed scheme suggests splitting the feeder cable in two cables and connecting it to a network through two rectifier units. Therefore, the split windings of the power transformer are supplied by a six-conductor feeder using unidirectional dc current. Unidirectional magnetic flux produced by the windings are summarised in the transformer core resulting ac flux to ensure a normal transformer operation. The proposed scheme was analysed under short and open-circuit faults. It has been shown that the short-circuit currents in the cable conductors and transformer windings are reduced in 1.41 times in comparison to a conventional scheme.\",\"PeriodicalId\":6670,\"journal\":{\"name\":\"2019 54th International Universities Power Engineering Conference (UPEC)\",\"volume\":\"298 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-11-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 54th International Universities Power Engineering Conference (UPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC.2019.8893544\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 54th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2019.8893544","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Reduction of Short Circuit Current using DC Transmission and Split-Winding Power Transformer
This paper discusses a new scheme to reduce the level of fault currents in the feeder cable and power transformer windings under short-circuit conditions. The proposed scheme suggests splitting the feeder cable in two cables and connecting it to a network through two rectifier units. Therefore, the split windings of the power transformer are supplied by a six-conductor feeder using unidirectional dc current. Unidirectional magnetic flux produced by the windings are summarised in the transformer core resulting ac flux to ensure a normal transformer operation. The proposed scheme was analysed under short and open-circuit faults. It has been shown that the short-circuit currents in the cable conductors and transformer windings are reduced in 1.41 times in comparison to a conventional scheme.