Yuri L. Lipovka, Vitaliy I. Belilovets, A. Y. Lipovka, Ю.Л. Липовка, В.И. Белиловец, А. Ю. Липовка
{"title":"水龙头长细比和应力集中对热网u型补偿器热膨胀负荷计算的影响","authors":"Yuri L. Lipovka, Vitaliy I. Belilovets, A. Y. Lipovka, Ю.Л. Липовка, В.И. Белиловец, А. Ю. Липовка","doi":"10.17516/1999-494x-2015-8-1-11-32","DOIUrl":null,"url":null,"abstract":"This article is about calculations of U - shaped regions of water heat network. The universal calculation algorithm is used for various geometric schemes and simple self-compensating pipeline sections. The influence of slenderness ratio and stress concentration factor in the smooth curved bends on voltages and maximum permissible flight compensated shoulders of U - shaped regions for different geometric configurations was taken into account in this work.","PeriodicalId":11548,"journal":{"name":"Engineering & Technologies","volume":"73 1","pages":"11-32"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Influence of Slenderness Ratio and Stress Concentration in Taps on Load Calculations to Thermal Expansion in U-shaped Compensators of Thermal Network\",\"authors\":\"Yuri L. Lipovka, Vitaliy I. Belilovets, A. Y. Lipovka, Ю.Л. Липовка, В.И. Белиловец, А. Ю. Липовка\",\"doi\":\"10.17516/1999-494x-2015-8-1-11-32\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article is about calculations of U - shaped regions of water heat network. The universal calculation algorithm is used for various geometric schemes and simple self-compensating pipeline sections. The influence of slenderness ratio and stress concentration factor in the smooth curved bends on voltages and maximum permissible flight compensated shoulders of U - shaped regions for different geometric configurations was taken into account in this work.\",\"PeriodicalId\":11548,\"journal\":{\"name\":\"Engineering & Technologies\",\"volume\":\"73 1\",\"pages\":\"11-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Engineering & Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17516/1999-494x-2015-8-1-11-32\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering & Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17516/1999-494x-2015-8-1-11-32","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Influence of Slenderness Ratio and Stress Concentration in Taps on Load Calculations to Thermal Expansion in U-shaped Compensators of Thermal Network
This article is about calculations of U - shaped regions of water heat network. The universal calculation algorithm is used for various geometric schemes and simple self-compensating pipeline sections. The influence of slenderness ratio and stress concentration factor in the smooth curved bends on voltages and maximum permissible flight compensated shoulders of U - shaped regions for different geometric configurations was taken into account in this work.