Yue Niu, Lihong Duan, Jingxin Zhang, Jiong Huang, Yueyang Zhai, W. Quan
{"title":"液晶可变缓速器在原子陀螺仪激光功率稳定系统中对环境温度漂移的抑制。","authors":"Yue Niu, Lihong Duan, Jingxin Zhang, Jiong Huang, Yueyang Zhai, W. Quan","doi":"10.1063/5.0049994","DOIUrl":null,"url":null,"abstract":"Laser power stabilization systems with liquid crystal variable retarders have been employed in miniaturized atomic gyroscopes for the merits of low power consumption and easy integration. However, the long-term power drift of the system output with ambient temperature significantly decreases the long-term performance of atomic gyroscopes. Here, we demonstrated a method of dynamic closed-loop control based on the combination of optical power drift and ambient temperature modeling. For a continuous 45 min operation within an ambient temperature variation range of 23.7-25.3 °C, the relative Allan deviation of the output optical power was decreased by one order of magnitude from 2.29 × 10-4 to 3.35 × 10-5 after 100 s averaging time. The long-term stability of the system was significantly improved. In addition, the scheme requires no additional thermal control device, preventing the introduction of extra electromagnetic interference, which is desirable in a miniaturized atomic gyroscope.","PeriodicalId":54761,"journal":{"name":"Journal of the Optical Society of America and Review of Scientific Instruments","volume":"36 1","pages":"043002"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Suppression of ambient temperature-caused drift in a laser power stabilization system with a liquid crystal variable retarder in atomic gyroscopes.\",\"authors\":\"Yue Niu, Lihong Duan, Jingxin Zhang, Jiong Huang, Yueyang Zhai, W. Quan\",\"doi\":\"10.1063/5.0049994\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Laser power stabilization systems with liquid crystal variable retarders have been employed in miniaturized atomic gyroscopes for the merits of low power consumption and easy integration. However, the long-term power drift of the system output with ambient temperature significantly decreases the long-term performance of atomic gyroscopes. Here, we demonstrated a method of dynamic closed-loop control based on the combination of optical power drift and ambient temperature modeling. For a continuous 45 min operation within an ambient temperature variation range of 23.7-25.3 °C, the relative Allan deviation of the output optical power was decreased by one order of magnitude from 2.29 × 10-4 to 3.35 × 10-5 after 100 s averaging time. The long-term stability of the system was significantly improved. In addition, the scheme requires no additional thermal control device, preventing the introduction of extra electromagnetic interference, which is desirable in a miniaturized atomic gyroscope.\",\"PeriodicalId\":54761,\"journal\":{\"name\":\"Journal of the Optical Society of America and Review of Scientific Instruments\",\"volume\":\"36 1\",\"pages\":\"043002\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Optical Society of America and Review of Scientific Instruments\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0049994\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Optical Society of America and Review of Scientific Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0049994","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Suppression of ambient temperature-caused drift in a laser power stabilization system with a liquid crystal variable retarder in atomic gyroscopes.
Laser power stabilization systems with liquid crystal variable retarders have been employed in miniaturized atomic gyroscopes for the merits of low power consumption and easy integration. However, the long-term power drift of the system output with ambient temperature significantly decreases the long-term performance of atomic gyroscopes. Here, we demonstrated a method of dynamic closed-loop control based on the combination of optical power drift and ambient temperature modeling. For a continuous 45 min operation within an ambient temperature variation range of 23.7-25.3 °C, the relative Allan deviation of the output optical power was decreased by one order of magnitude from 2.29 × 10-4 to 3.35 × 10-5 after 100 s averaging time. The long-term stability of the system was significantly improved. In addition, the scheme requires no additional thermal control device, preventing the introduction of extra electromagnetic interference, which is desirable in a miniaturized atomic gyroscope.