Flash-CIDNP实验优化

Martin Goez
{"title":"Flash-CIDNP实验优化","authors":"Martin Goez","doi":"10.1006/jmra.1996.0230","DOIUrl":null,"url":null,"abstract":"<div><p>The time resolution of flash-CIDNP experiments (time-resolved measurements of photochemically induced dynamic nuclear polarizations) can be increased by using NMR observation pulses that are delayed from scan to scan by an interval shorter than the pulse duration, and which need not be short on the time scale of the chemical kinetics. Recording a kinetic curve with such pulses amounts to passing it through a low pass filter. The dependence of the transfer function of the latter on duration and shape of the<em>B</em><sub>1</sub>pulse, as well as the influence of the flip angle are analyzed. It is shown that, in order to achieve maximum sensitivity, flip angle and acquisition time must be optimized in a way different from that used in conventional NMR experiments. With regard to hardware-dependent parameters, the time resolution of the method is basically limited by the rise time of the<em>B</em><sub>1</sub>pulses; in contrast, in the regime where the transfer function is determined by the pulse width, there is a trade-off between sensitivity and time resolution, and the strength of the<em>B</em><sub>1</sub>field is the most important factor.</p></div>","PeriodicalId":16165,"journal":{"name":"Journal of Magnetic Resonance, Series A","volume":"123 2","pages":"Pages 161-167"},"PeriodicalIF":0.0000,"publicationDate":"1996-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1006/jmra.1996.0230","citationCount":"4","resultStr":"{\"title\":\"Optimization of Flash-CIDNP Experiments\",\"authors\":\"Martin Goez\",\"doi\":\"10.1006/jmra.1996.0230\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The time resolution of flash-CIDNP experiments (time-resolved measurements of photochemically induced dynamic nuclear polarizations) can be increased by using NMR observation pulses that are delayed from scan to scan by an interval shorter than the pulse duration, and which need not be short on the time scale of the chemical kinetics. Recording a kinetic curve with such pulses amounts to passing it through a low pass filter. The dependence of the transfer function of the latter on duration and shape of the<em>B</em><sub>1</sub>pulse, as well as the influence of the flip angle are analyzed. It is shown that, in order to achieve maximum sensitivity, flip angle and acquisition time must be optimized in a way different from that used in conventional NMR experiments. With regard to hardware-dependent parameters, the time resolution of the method is basically limited by the rise time of the<em>B</em><sub>1</sub>pulses; in contrast, in the regime where the transfer function is determined by the pulse width, there is a trade-off between sensitivity and time resolution, and the strength of the<em>B</em><sub>1</sub>field is the most important factor.</p></div>\",\"PeriodicalId\":16165,\"journal\":{\"name\":\"Journal of Magnetic Resonance, Series A\",\"volume\":\"123 2\",\"pages\":\"Pages 161-167\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1006/jmra.1996.0230\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance, Series A\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1064185896902302\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance, Series A","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1064185896902302","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

利用比脉冲持续时间短的核磁共振观测脉冲,可以提高flash-CIDNP实验(光化学诱导的动态核极化的时间分辨测量)的时间分辨率,并且在化学动力学的时间尺度上不需要太短。用这样的脉冲记录动力学曲线相当于让它通过一个低通滤波器。分析了后者的传递函数与b脉冲持续时间和形状的关系,以及翻转角的影响。结果表明,为了获得最大的灵敏度,必须采用不同于传统核磁共振实验的方式优化翻转角度和采集时间。对于与硬件相关的参数,该方法的时间分辨率基本上受到b1脉冲上升时间的限制;相反,在传递函数由脉冲宽度决定的情况下,在灵敏度和时间分辨率之间存在权衡,并且b1场的强度是最重要的因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimization of Flash-CIDNP Experiments

The time resolution of flash-CIDNP experiments (time-resolved measurements of photochemically induced dynamic nuclear polarizations) can be increased by using NMR observation pulses that are delayed from scan to scan by an interval shorter than the pulse duration, and which need not be short on the time scale of the chemical kinetics. Recording a kinetic curve with such pulses amounts to passing it through a low pass filter. The dependence of the transfer function of the latter on duration and shape of theB1pulse, as well as the influence of the flip angle are analyzed. It is shown that, in order to achieve maximum sensitivity, flip angle and acquisition time must be optimized in a way different from that used in conventional NMR experiments. With regard to hardware-dependent parameters, the time resolution of the method is basically limited by the rise time of theB1pulses; in contrast, in the regime where the transfer function is determined by the pulse width, there is a trade-off between sensitivity and time resolution, and the strength of theB1field is the most important factor.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信