{"title":"影响吸入器体外试验的因素","authors":"C. Dickens, J. Mcaughey, D. Knight, S. Baker","doi":"10.1089/JAM.1994.7.193","DOIUrl":null,"url":null,"abstract":"ABSTRACT By examining data for various inhalers under a range of conditions, we have demonstrated the effect of air flow, humidity, and the shape of an artificial throat, on delivery for a number of different inhaler types. The importance of these effects will be discussed by showing how the achievable flow through an inhaler can be estimated, indicating that standard test conditions of 60 1/min flow may be inappropriate for some inhaler types, and may over estimate their performance.","PeriodicalId":14879,"journal":{"name":"Journal of Aerosol Medicine-deposition Clearance and Effects in The Lung","volume":"5 1","pages":"193-196"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Factors Affecting In Vitro Testing of Inhalers\",\"authors\":\"C. Dickens, J. Mcaughey, D. Knight, S. Baker\",\"doi\":\"10.1089/JAM.1994.7.193\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"ABSTRACT By examining data for various inhalers under a range of conditions, we have demonstrated the effect of air flow, humidity, and the shape of an artificial throat, on delivery for a number of different inhaler types. The importance of these effects will be discussed by showing how the achievable flow through an inhaler can be estimated, indicating that standard test conditions of 60 1/min flow may be inappropriate for some inhaler types, and may over estimate their performance.\",\"PeriodicalId\":14879,\"journal\":{\"name\":\"Journal of Aerosol Medicine-deposition Clearance and Effects in The Lung\",\"volume\":\"5 1\",\"pages\":\"193-196\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Aerosol Medicine-deposition Clearance and Effects in The Lung\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/JAM.1994.7.193\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Aerosol Medicine-deposition Clearance and Effects in The Lung","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/JAM.1994.7.193","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
ABSTRACT By examining data for various inhalers under a range of conditions, we have demonstrated the effect of air flow, humidity, and the shape of an artificial throat, on delivery for a number of different inhaler types. The importance of these effects will be discussed by showing how the achievable flow through an inhaler can be estimated, indicating that standard test conditions of 60 1/min flow may be inappropriate for some inhaler types, and may over estimate their performance.