带储能装置的多区域混合电源系统的频率调节

IF 0.5 Q4 COMPUTER SCIENCE, SOFTWARE ENGINEERING
Ch. Naga Sai Kalyan, M. Kumar, B. S. Goud, Hossein Shahinzadeh, Ch. Rami Reddy, M. Kiran Kumar
{"title":"带储能装置的多区域混合电源系统的频率调节","authors":"Ch. Naga Sai Kalyan, M. Kumar, B. S. Goud, Hossein Shahinzadeh, Ch. Rami Reddy, M. Kiran Kumar","doi":"10.1109/rtest56034.2022.9850101","DOIUrl":null,"url":null,"abstract":"In this paper, a three degree-of-freedom PID (3DOFPID) fine-tuned using a seagull optimization algorithm (SOA) is presented as a secondary regulator for a multi-area hybrid source (MAHS) interconnected power system. Area-1 of MAHS is subjugated with a perturbation of 10% step load. Moreover, the superiority of the presented SOA tuned 3DOFPID controller is demonstrated with performances of other control techniques that have been reported in recent literature. To further enhance the dynamical behaviour of MAHS during perturbed conditions, energy storage devices (ESDs) such as redox flow batteries (RFBs) and superconducting magnetic energy storage (SMES) devices are placed in each area of the MAHS power system one after the other. Simulation results reveal the dominancy of SMES in handling the deviations in MAHS power system performance compared to RFBs.","PeriodicalId":38446,"journal":{"name":"International Journal of Embedded and Real-Time Communication Systems (IJERTCS)","volume":"197 1","pages":"1-5"},"PeriodicalIF":0.5000,"publicationDate":"2022-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Frequency Regulation of Multi Area Hybrid Source Power System with Energy Storage Devices\",\"authors\":\"Ch. Naga Sai Kalyan, M. Kumar, B. S. Goud, Hossein Shahinzadeh, Ch. Rami Reddy, M. Kiran Kumar\",\"doi\":\"10.1109/rtest56034.2022.9850101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a three degree-of-freedom PID (3DOFPID) fine-tuned using a seagull optimization algorithm (SOA) is presented as a secondary regulator for a multi-area hybrid source (MAHS) interconnected power system. Area-1 of MAHS is subjugated with a perturbation of 10% step load. Moreover, the superiority of the presented SOA tuned 3DOFPID controller is demonstrated with performances of other control techniques that have been reported in recent literature. To further enhance the dynamical behaviour of MAHS during perturbed conditions, energy storage devices (ESDs) such as redox flow batteries (RFBs) and superconducting magnetic energy storage (SMES) devices are placed in each area of the MAHS power system one after the other. Simulation results reveal the dominancy of SMES in handling the deviations in MAHS power system performance compared to RFBs.\",\"PeriodicalId\":38446,\"journal\":{\"name\":\"International Journal of Embedded and Real-Time Communication Systems (IJERTCS)\",\"volume\":\"197 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2022-05-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Embedded and Real-Time Communication Systems (IJERTCS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/rtest56034.2022.9850101\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"COMPUTER SCIENCE, SOFTWARE ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Embedded and Real-Time Communication Systems (IJERTCS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/rtest56034.2022.9850101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"COMPUTER SCIENCE, SOFTWARE ENGINEERING","Score":null,"Total":0}
引用次数: 2

摘要

本文提出了一种采用海鸥优化算法(SOA)微调的三自由度PID (3DOFPID)作为多区域混合电源(MAHS)互联电力系统的二次调节器。MAHS的Area-1受到10%阶跃载荷的扰动。此外,所提出的SOA调优3DOFPID控制器的优越性与最近文献中报道的其他控制技术的性能一起得到了证明。为了进一步增强MAHS在扰动条件下的动力学行为,在MAHS电力系统的每个区域依次放置了能量存储设备(esd),如氧化还原液流电池(rbs)和超导磁储能(SMES)设备。仿真结果表明,中小企业在处理MAHS电力系统性能偏差方面比rbf更具优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Frequency Regulation of Multi Area Hybrid Source Power System with Energy Storage Devices
In this paper, a three degree-of-freedom PID (3DOFPID) fine-tuned using a seagull optimization algorithm (SOA) is presented as a secondary regulator for a multi-area hybrid source (MAHS) interconnected power system. Area-1 of MAHS is subjugated with a perturbation of 10% step load. Moreover, the superiority of the presented SOA tuned 3DOFPID controller is demonstrated with performances of other control techniques that have been reported in recent literature. To further enhance the dynamical behaviour of MAHS during perturbed conditions, energy storage devices (ESDs) such as redox flow batteries (RFBs) and superconducting magnetic energy storage (SMES) devices are placed in each area of the MAHS power system one after the other. Simulation results reveal the dominancy of SMES in handling the deviations in MAHS power system performance compared to RFBs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
14.30%
发文量
17
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信