{"title":"利用交流电热流对片内混合、泵送和浓缩的影响","authors":"R. H. Vafaie","doi":"10.2174/2210681208666180321142455","DOIUrl":null,"url":null,"abstract":"Microfluidic manipulation (including: pumping, mixing and concentrating effects) is highly challengeable for bioengineering and on-chip analysis applications such as point-of-care immune-detection systems. In this research we propose a configurable electrode structure to form various manipulation effects including pumping, mixing and concentrating processes by applying an Alternate Current (AC) electrokinetically-driven flow.By applying an inhomogeneous electric field causes temperature rise accompanied by temperature gradients generation inside the microchannel. As a result, an AC electrothermal flow generates inside the channel, which is efficient to generate mixing, pumping and concentrating effects.The proposed system is studied numerically by Finite-Element-Method, Based on the results, a) bulk fluid velocity of 100 µm/s is achieved by exciting the electrodes in pumping mode, b) complete mixing efficiency is observed in mixing mode, c) for antibody-antigen binding process (concentrating mode), the surface reaction increases by the factor of 9 after 5 seconds of sample loading. Results reveal that the system is highly efficient for bio-fluid mediums.AC electrothermal fluid manipulation process was investigated numerically inside a microchannel for biological buffers. Back and forth fluid motions, clockwise/counter-clockwise rotational vortexes and also antibody-antigen linking enhancement were achieved by engineering the specific electrode patterns. The manipulation efficiency improves by increasing both the amplitude of electric potential and the ionic strength of biofluid. As a result, our proposed configurable device is of interest for onchip immunoassays and point-of-care devices.","PeriodicalId":18979,"journal":{"name":"Nanoscience & Nanotechnology-Asia","volume":"31 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On-chip Mixing, Pumping and Concentrating Effects by Using AC Electrothermal Flow\",\"authors\":\"R. H. Vafaie\",\"doi\":\"10.2174/2210681208666180321142455\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Microfluidic manipulation (including: pumping, mixing and concentrating effects) is highly challengeable for bioengineering and on-chip analysis applications such as point-of-care immune-detection systems. In this research we propose a configurable electrode structure to form various manipulation effects including pumping, mixing and concentrating processes by applying an Alternate Current (AC) electrokinetically-driven flow.By applying an inhomogeneous electric field causes temperature rise accompanied by temperature gradients generation inside the microchannel. As a result, an AC electrothermal flow generates inside the channel, which is efficient to generate mixing, pumping and concentrating effects.The proposed system is studied numerically by Finite-Element-Method, Based on the results, a) bulk fluid velocity of 100 µm/s is achieved by exciting the electrodes in pumping mode, b) complete mixing efficiency is observed in mixing mode, c) for antibody-antigen binding process (concentrating mode), the surface reaction increases by the factor of 9 after 5 seconds of sample loading. Results reveal that the system is highly efficient for bio-fluid mediums.AC electrothermal fluid manipulation process was investigated numerically inside a microchannel for biological buffers. Back and forth fluid motions, clockwise/counter-clockwise rotational vortexes and also antibody-antigen linking enhancement were achieved by engineering the specific electrode patterns. The manipulation efficiency improves by increasing both the amplitude of electric potential and the ionic strength of biofluid. As a result, our proposed configurable device is of interest for onchip immunoassays and point-of-care devices.\",\"PeriodicalId\":18979,\"journal\":{\"name\":\"Nanoscience & Nanotechnology-Asia\",\"volume\":\"31 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nanoscience & Nanotechnology-Asia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/2210681208666180321142455\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanoscience & Nanotechnology-Asia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/2210681208666180321142455","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On-chip Mixing, Pumping and Concentrating Effects by Using AC Electrothermal Flow
Microfluidic manipulation (including: pumping, mixing and concentrating effects) is highly challengeable for bioengineering and on-chip analysis applications such as point-of-care immune-detection systems. In this research we propose a configurable electrode structure to form various manipulation effects including pumping, mixing and concentrating processes by applying an Alternate Current (AC) electrokinetically-driven flow.By applying an inhomogeneous electric field causes temperature rise accompanied by temperature gradients generation inside the microchannel. As a result, an AC electrothermal flow generates inside the channel, which is efficient to generate mixing, pumping and concentrating effects.The proposed system is studied numerically by Finite-Element-Method, Based on the results, a) bulk fluid velocity of 100 µm/s is achieved by exciting the electrodes in pumping mode, b) complete mixing efficiency is observed in mixing mode, c) for antibody-antigen binding process (concentrating mode), the surface reaction increases by the factor of 9 after 5 seconds of sample loading. Results reveal that the system is highly efficient for bio-fluid mediums.AC electrothermal fluid manipulation process was investigated numerically inside a microchannel for biological buffers. Back and forth fluid motions, clockwise/counter-clockwise rotational vortexes and also antibody-antigen linking enhancement were achieved by engineering the specific electrode patterns. The manipulation efficiency improves by increasing both the amplitude of electric potential and the ionic strength of biofluid. As a result, our proposed configurable device is of interest for onchip immunoassays and point-of-care devices.