定子绕组绝缘非线性特性研究的一种广义方法

C. Pinto
{"title":"定子绕组绝缘非线性特性研究的一种广义方法","authors":"C. Pinto","doi":"10.1109/ICSD.1998.709340","DOIUrl":null,"url":null,"abstract":"Measurements performed on stator winding insulation indicate variations in capacitance and tan /spl delta/ values with voltage even in the absence of partial discharge activity. One of the most obvious reasons for this variation is the presence of the non-linear field stress grading system employed at the slot ends. Other reasons include interfacial and space charge polarization phenomena, due to a variety of reasons including contamination of the windings, as well as, the effects of electrostatic forces on delaminated stator insulation. As partial discharge activity results in change in the instantaneous capacitance with voltage, it could also be considered as a case of non linear behaviour of the insulation. The paper discusses a generalized approach to study the influence of non-linear behaviour on the variations of capacitance and losses. Case studies are employed to illustrate the usefulness of measurements on the stator windings in service.","PeriodicalId":13148,"journal":{"name":"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)","volume":"24 1","pages":"528-532"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"A generalized approach for the study of the non linear behaviour of stator winding insulation\",\"authors\":\"C. Pinto\",\"doi\":\"10.1109/ICSD.1998.709340\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurements performed on stator winding insulation indicate variations in capacitance and tan /spl delta/ values with voltage even in the absence of partial discharge activity. One of the most obvious reasons for this variation is the presence of the non-linear field stress grading system employed at the slot ends. Other reasons include interfacial and space charge polarization phenomena, due to a variety of reasons including contamination of the windings, as well as, the effects of electrostatic forces on delaminated stator insulation. As partial discharge activity results in change in the instantaneous capacitance with voltage, it could also be considered as a case of non linear behaviour of the insulation. The paper discusses a generalized approach to study the influence of non-linear behaviour on the variations of capacitance and losses. Case studies are employed to illustrate the usefulness of measurements on the stator windings in service.\",\"PeriodicalId\":13148,\"journal\":{\"name\":\"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)\",\"volume\":\"24 1\",\"pages\":\"528-532\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSD.1998.709340\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.1998.709340","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

对定子绕组绝缘进行的测量表明,即使在没有局部放电活动的情况下,电容和tan /spl δ /值也随电压的变化而变化。造成这种变化的一个最明显的原因是在槽端采用了非线性应力场分级系统。其他原因包括界面和空间电荷极化现象,这是由于各种原因造成的,包括绕组的污染,以及静电力对分层定子绝缘的影响。由于局部放电活动导致瞬时电容随电压的变化,它也可以被认为是绝缘非线性行为的一种情况。本文讨论了一种研究非线性行为对电容和损耗变化影响的广义方法。案例研究说明了在使用中对定子绕组进行测量的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A generalized approach for the study of the non linear behaviour of stator winding insulation
Measurements performed on stator winding insulation indicate variations in capacitance and tan /spl delta/ values with voltage even in the absence of partial discharge activity. One of the most obvious reasons for this variation is the presence of the non-linear field stress grading system employed at the slot ends. Other reasons include interfacial and space charge polarization phenomena, due to a variety of reasons including contamination of the windings, as well as, the effects of electrostatic forces on delaminated stator insulation. As partial discharge activity results in change in the instantaneous capacitance with voltage, it could also be considered as a case of non linear behaviour of the insulation. The paper discusses a generalized approach to study the influence of non-linear behaviour on the variations of capacitance and losses. Case studies are employed to illustrate the usefulness of measurements on the stator windings in service.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信