{"title":"基于CFD的小瓶内冻干升华质量通量的测定","authors":"M. Zadravec, J. Ravnik, Ziga Casar, M. Hriberšek","doi":"10.2495/CMEM-V8-N1-47-60","DOIUrl":null,"url":null,"abstract":"In the case of computational models of lyophilization in a vial, the intensity of drying is to a large extent controlled by the pressure conditions above the drying surface, as the drying driving force is the pressure difference between the saturation vapour pressure at the sublimation interface and the vapour partial pressure above the drying substance. In majority of studies, the effect of the vial and the rubber stopper geometry on the pressure conditions inside the vial is either neglected or taken into account by an estimated additional vapour pressure increase inside the vial. As the pressure conditions depend on the flow of sublimated solvent inside the vial-stopper conduit geometry, but are experimentally difficult to determine, a dedicated CFD analysis of flow conditions inside the vial-stopper channel was performed. The influence of imposing of the no-slip and slip conditions on the solid surfaces on the pressure drop in the system was studied and the effect of the increased partial pressure of the solvent on the sublimation rate was evaluated for the starting phase of the lyophilization by implementing the Stefan’s one sided diffusion model. The computational results show, that the effect of the additional flow resistance due to the vial conduit and the stopper is most significant at lowest system temperatures, with as much as 30% increase in vapour pressure inside the vial.","PeriodicalId":22520,"journal":{"name":"THE INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS AND EXPERIMENTAL MEASUREMENTS","volume":"52 1","pages":"47-60"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"CFD based determination of sublimation mass flux for lyophilization inside a vial\",\"authors\":\"M. Zadravec, J. Ravnik, Ziga Casar, M. Hriberšek\",\"doi\":\"10.2495/CMEM-V8-N1-47-60\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the case of computational models of lyophilization in a vial, the intensity of drying is to a large extent controlled by the pressure conditions above the drying surface, as the drying driving force is the pressure difference between the saturation vapour pressure at the sublimation interface and the vapour partial pressure above the drying substance. In majority of studies, the effect of the vial and the rubber stopper geometry on the pressure conditions inside the vial is either neglected or taken into account by an estimated additional vapour pressure increase inside the vial. As the pressure conditions depend on the flow of sublimated solvent inside the vial-stopper conduit geometry, but are experimentally difficult to determine, a dedicated CFD analysis of flow conditions inside the vial-stopper channel was performed. The influence of imposing of the no-slip and slip conditions on the solid surfaces on the pressure drop in the system was studied and the effect of the increased partial pressure of the solvent on the sublimation rate was evaluated for the starting phase of the lyophilization by implementing the Stefan’s one sided diffusion model. The computational results show, that the effect of the additional flow resistance due to the vial conduit and the stopper is most significant at lowest system temperatures, with as much as 30% increase in vapour pressure inside the vial.\",\"PeriodicalId\":22520,\"journal\":{\"name\":\"THE INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS AND EXPERIMENTAL MEASUREMENTS\",\"volume\":\"52 1\",\"pages\":\"47-60\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"THE INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS AND EXPERIMENTAL MEASUREMENTS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2495/CMEM-V8-N1-47-60\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"THE INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS AND EXPERIMENTAL MEASUREMENTS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2495/CMEM-V8-N1-47-60","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在小瓶冻干计算模型中,干燥强度在很大程度上由干燥表面上方的压力条件控制,因为干燥驱动力是升华界面处的饱和蒸汽压与干燥物质上方的蒸汽分压之间的压差。在大多数研究中,小瓶和橡胶塞几何形状对小瓶内压力条件的影响要么被忽略,要么被估计的小瓶内额外蒸汽压力增加考虑在内。由于压力条件取决于升华溶剂在小塞管内的流动几何形状,但在实验上难以确定,因此对小塞管内的流动条件进行了专门的CFD分析。采用Stefan单侧扩散模型,研究了固体表面施加无滑移和滑移条件对系统压降的影响,并评估了溶剂分压的增加对冻干起始阶段升华速率的影响。计算结果表明,在最低的系统温度下,由于小瓶导管和瓶塞造成的额外流动阻力的影响最为显著,小瓶内的蒸汽压力增加了30%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CFD based determination of sublimation mass flux for lyophilization inside a vial
In the case of computational models of lyophilization in a vial, the intensity of drying is to a large extent controlled by the pressure conditions above the drying surface, as the drying driving force is the pressure difference between the saturation vapour pressure at the sublimation interface and the vapour partial pressure above the drying substance. In majority of studies, the effect of the vial and the rubber stopper geometry on the pressure conditions inside the vial is either neglected or taken into account by an estimated additional vapour pressure increase inside the vial. As the pressure conditions depend on the flow of sublimated solvent inside the vial-stopper conduit geometry, but are experimentally difficult to determine, a dedicated CFD analysis of flow conditions inside the vial-stopper channel was performed. The influence of imposing of the no-slip and slip conditions on the solid surfaces on the pressure drop in the system was studied and the effect of the increased partial pressure of the solvent on the sublimation rate was evaluated for the starting phase of the lyophilization by implementing the Stefan’s one sided diffusion model. The computational results show, that the effect of the additional flow resistance due to the vial conduit and the stopper is most significant at lowest system temperatures, with as much as 30% increase in vapour pressure inside the vial.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信