{"title":"地震荷载作用下土工格室加筋边坡的校正欠塑性土本构模型","authors":"A. Ardakani, A. Namaei","doi":"10.22075/JRCE.2021.21425.1446","DOIUrl":null,"url":null,"abstract":"This study evaluates geocell reinforced slope behavior under seismic loading using calibrated hypoplastic soil constitutive model. The constitutive soil model used in this simulation was calibrated for poorly graded dense sand by conducting a series of triaxial and odometer tests. A three dimensional analysis is carried out to simulate geocells and this soil model using the finite element software PLAXIS3D. To investigate the geocell seismic behavior, the lateral displacement, induced tensile force in geocell, slope stability and frequency content effect have been assessed. Furthermore, a comparison has been made among hypoplastic, Hardening soil with small strain and Mohr-Coulomb model. The obtained results indicated that the volumetric plastic strain and intergranular strain consideration by hypoplastic model had a significant effect on the lateral displacement of the reinforced and unreinforced slope. Using the geocell layers leaded to decrease the plastic points. This behavior caused to decrease the estimated results difference when performing three constitutive models as soil failure criterion. Also, the tensile force showed hypoplastic model was not sensitive to the earthquake reversible force. In addition, it was found that the geocells lost their effect when the PGA increased and the slope was apt to fail.","PeriodicalId":52415,"journal":{"name":"Journal of Rehabilitation in Civil Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Geocell reinforced slope behavior under seismic loading using calibrated hypoplastic soil constitutive model\",\"authors\":\"A. Ardakani, A. Namaei\",\"doi\":\"10.22075/JRCE.2021.21425.1446\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study evaluates geocell reinforced slope behavior under seismic loading using calibrated hypoplastic soil constitutive model. The constitutive soil model used in this simulation was calibrated for poorly graded dense sand by conducting a series of triaxial and odometer tests. A three dimensional analysis is carried out to simulate geocells and this soil model using the finite element software PLAXIS3D. To investigate the geocell seismic behavior, the lateral displacement, induced tensile force in geocell, slope stability and frequency content effect have been assessed. Furthermore, a comparison has been made among hypoplastic, Hardening soil with small strain and Mohr-Coulomb model. The obtained results indicated that the volumetric plastic strain and intergranular strain consideration by hypoplastic model had a significant effect on the lateral displacement of the reinforced and unreinforced slope. Using the geocell layers leaded to decrease the plastic points. This behavior caused to decrease the estimated results difference when performing three constitutive models as soil failure criterion. Also, the tensile force showed hypoplastic model was not sensitive to the earthquake reversible force. In addition, it was found that the geocells lost their effect when the PGA increased and the slope was apt to fail.\",\"PeriodicalId\":52415,\"journal\":{\"name\":\"Journal of Rehabilitation in Civil Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Rehabilitation in Civil Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22075/JRCE.2021.21425.1446\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Rehabilitation in Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22075/JRCE.2021.21425.1446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 2

摘要

本研究利用校正后的低塑性土本构模型评估土工格室加筋边坡在地震荷载作用下的性能。模拟中使用的本构土模型是通过进行一系列三轴和里程计试验对差级配致密砂进行校准的。利用有限元软件PLAXIS3D对土工胞和该土模型进行了三维模拟分析。为了研究土工格室的抗震性能,对土工格室的横向位移、诱导拉伸力、边坡稳定性和频率含量效应进行了评估。在此基础上,对低塑性、小应变硬化土和Mohr-Coulomb模型进行了比较。结果表明,考虑体塑性应变和欠塑性模型的晶间应变对加筋和未加筋边坡的侧向位移有显著影响。土工格室层的使用减少了塑性点。这种行为使得三种本构模型作为土失稳判据时的估计结果差异减小。拉伸力表明,发育不良模型对地震可逆力不敏感。此外,当PGA增大时,土工格室失去了作用,边坡容易破坏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Geocell reinforced slope behavior under seismic loading using calibrated hypoplastic soil constitutive model
This study evaluates geocell reinforced slope behavior under seismic loading using calibrated hypoplastic soil constitutive model. The constitutive soil model used in this simulation was calibrated for poorly graded dense sand by conducting a series of triaxial and odometer tests. A three dimensional analysis is carried out to simulate geocells and this soil model using the finite element software PLAXIS3D. To investigate the geocell seismic behavior, the lateral displacement, induced tensile force in geocell, slope stability and frequency content effect have been assessed. Furthermore, a comparison has been made among hypoplastic, Hardening soil with small strain and Mohr-Coulomb model. The obtained results indicated that the volumetric plastic strain and intergranular strain consideration by hypoplastic model had a significant effect on the lateral displacement of the reinforced and unreinforced slope. Using the geocell layers leaded to decrease the plastic points. This behavior caused to decrease the estimated results difference when performing three constitutive models as soil failure criterion. Also, the tensile force showed hypoplastic model was not sensitive to the earthquake reversible force. In addition, it was found that the geocells lost their effect when the PGA increased and the slope was apt to fail.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Rehabilitation in Civil Engineering
Journal of Rehabilitation in Civil Engineering Engineering-Building and Construction
CiteScore
1.60
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信