药物明胶薄膜降解动力学的无线筛选

H. Jiang, M. Ochoa, J. H. Park, A. Otte, R. Pinal, B. Ziaie
{"title":"药物明胶薄膜降解动力学的无线筛选","authors":"H. Jiang, M. Ochoa, J. H. Park, A. Otte, R. Pinal, B. Ziaie","doi":"10.1109/TRANSDUCERS.2015.7181319","DOIUrl":null,"url":null,"abstract":"We have developed a wireless sensing scheme for rapid screening of gelatin film physical degradation. The technique presents a new method for delineating the initial swelling (capacitive change) and subsequent dissolution (inductive change) phases. This is accomplished by incorporating super-paramagnetic nanoparticles into a gelatin film that is immobilized on top of a planar inductor. The degradation kinetics are measured wirelessly to identify the swelling and dissolution phases with sensitivities of 2313.4 kHz per absorbance unit during the first 60 minutes and 2214.2 kHz per absorbance unit from 60 minutes to 540 minutes.","PeriodicalId":6465,"journal":{"name":"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Wireless screenning of degradation kinetics in pharmaceutical gelatin films\",\"authors\":\"H. Jiang, M. Ochoa, J. H. Park, A. Otte, R. Pinal, B. Ziaie\",\"doi\":\"10.1109/TRANSDUCERS.2015.7181319\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have developed a wireless sensing scheme for rapid screening of gelatin film physical degradation. The technique presents a new method for delineating the initial swelling (capacitive change) and subsequent dissolution (inductive change) phases. This is accomplished by incorporating super-paramagnetic nanoparticles into a gelatin film that is immobilized on top of a planar inductor. The degradation kinetics are measured wirelessly to identify the swelling and dissolution phases with sensitivities of 2313.4 kHz per absorbance unit during the first 60 minutes and 2214.2 kHz per absorbance unit from 60 minutes to 540 minutes.\",\"PeriodicalId\":6465,\"journal\":{\"name\":\"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TRANSDUCERS.2015.7181319\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Transducers - 2015 18th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRANSDUCERS.2015.7181319","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

我们开发了一种用于明胶薄膜物理降解快速筛选的无线传感方案。该技术提出了一种描述初始溶胀(电容变化)和随后溶解(电感变化)相的新方法。这是通过将超顺磁性纳米颗粒结合到固定在平面电感器顶部的明胶薄膜中来实现的。通过无线测量降解动力学来识别溶胀和溶解相,前60分钟的灵敏度为2313.4 kHz /吸光度单位,60分钟至540分钟的灵敏度为2214.2 kHz /吸光度单位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wireless screenning of degradation kinetics in pharmaceutical gelatin films
We have developed a wireless sensing scheme for rapid screening of gelatin film physical degradation. The technique presents a new method for delineating the initial swelling (capacitive change) and subsequent dissolution (inductive change) phases. This is accomplished by incorporating super-paramagnetic nanoparticles into a gelatin film that is immobilized on top of a planar inductor. The degradation kinetics are measured wirelessly to identify the swelling and dissolution phases with sensitivities of 2313.4 kHz per absorbance unit during the first 60 minutes and 2214.2 kHz per absorbance unit from 60 minutes to 540 minutes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信