G. Zhou, Hong Zheng, Hao Du, Qilong Wang, Xiangrong Chen
{"title":"聚丙烯层压纸直流导电性的研究","authors":"G. Zhou, Hong Zheng, Hao Du, Qilong Wang, Xiangrong Chen","doi":"10.1109/AEERO52475.2021.9708160","DOIUrl":null,"url":null,"abstract":"DC electric field analysis should be carried out for the insulation design of dc high-temperature superconducting (HTS) equipment. For that purpose, the conductivity of PPLP was measured under room temperature and liquid-nitrogen temperature. The testing results show that the conductivity of single PPLP is 2.02 × 10-15 S/m at liquid-nitrogen temperature and 2.86 × 10-15 S/m at room temperature. The threshold electric field of PPLP insulation at liquid-nitrogen temperature and room temperature is 17.5 kV/mm. When the applied electric field is lower than 17.5 kV/mm, the conductivity of PPLP does not change with the electric field strength. When the applied electric field is higher than 17.5 kV/mm, the conductivity of PPLP increases with the electric field strength. Different layers of PPLP have the same electric field threshold, but the conductivity is not the same.","PeriodicalId":6828,"journal":{"name":"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)","volume":"1 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study on DC Conductivity Characteristics of Polypropylene Laminated Paper\",\"authors\":\"G. Zhou, Hong Zheng, Hao Du, Qilong Wang, Xiangrong Chen\",\"doi\":\"10.1109/AEERO52475.2021.9708160\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"DC electric field analysis should be carried out for the insulation design of dc high-temperature superconducting (HTS) equipment. For that purpose, the conductivity of PPLP was measured under room temperature and liquid-nitrogen temperature. The testing results show that the conductivity of single PPLP is 2.02 × 10-15 S/m at liquid-nitrogen temperature and 2.86 × 10-15 S/m at room temperature. The threshold electric field of PPLP insulation at liquid-nitrogen temperature and room temperature is 17.5 kV/mm. When the applied electric field is lower than 17.5 kV/mm, the conductivity of PPLP does not change with the electric field strength. When the applied electric field is higher than 17.5 kV/mm, the conductivity of PPLP increases with the electric field strength. Different layers of PPLP have the same electric field threshold, but the conductivity is not the same.\",\"PeriodicalId\":6828,\"journal\":{\"name\":\"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)\",\"volume\":\"1 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEERO52475.2021.9708160\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Advanced Electrical Equipment and Reliable Operation (AEERO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEERO52475.2021.9708160","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Study on DC Conductivity Characteristics of Polypropylene Laminated Paper
DC electric field analysis should be carried out for the insulation design of dc high-temperature superconducting (HTS) equipment. For that purpose, the conductivity of PPLP was measured under room temperature and liquid-nitrogen temperature. The testing results show that the conductivity of single PPLP is 2.02 × 10-15 S/m at liquid-nitrogen temperature and 2.86 × 10-15 S/m at room temperature. The threshold electric field of PPLP insulation at liquid-nitrogen temperature and room temperature is 17.5 kV/mm. When the applied electric field is lower than 17.5 kV/mm, the conductivity of PPLP does not change with the electric field strength. When the applied electric field is higher than 17.5 kV/mm, the conductivity of PPLP increases with the electric field strength. Different layers of PPLP have the same electric field threshold, but the conductivity is not the same.