Luca Sant, A. Fant, S. Stojanovic, S. Fabbro, J. Ceballos
{"title":"一种132b光学近距离传感器系统,具有130klx的环境光抑制能力,能够监测心率和血氧饱和度","authors":"Luca Sant, A. Fant, S. Stojanovic, S. Fabbro, J. Ceballos","doi":"10.1109/ESSCIRC.2015.7313905","DOIUrl":null,"url":null,"abstract":"A system for measuring optical proximity based on reflection of modulated light is presented. Its novel input stage topology comprising an AC coupled TIA and a two stage DC rejection circuit based on a synthesized inductive impedance, provides readouts with a resolution better than 13.2 ENOB. This allows the sensor system to be used without modifications also for heart rate and blood oximetry monitoring.","PeriodicalId":11845,"journal":{"name":"ESSCIRC Conference 2015 - 41st European Solid-State Circuits Conference (ESSCIRC)","volume":"13 1","pages":"372-375"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A 13.2b optical proximity sensor system with 130klx ambient light rejection capable of heart rate and blood oximetry monitoring\",\"authors\":\"Luca Sant, A. Fant, S. Stojanovic, S. Fabbro, J. Ceballos\",\"doi\":\"10.1109/ESSCIRC.2015.7313905\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A system for measuring optical proximity based on reflection of modulated light is presented. Its novel input stage topology comprising an AC coupled TIA and a two stage DC rejection circuit based on a synthesized inductive impedance, provides readouts with a resolution better than 13.2 ENOB. This allows the sensor system to be used without modifications also for heart rate and blood oximetry monitoring.\",\"PeriodicalId\":11845,\"journal\":{\"name\":\"ESSCIRC Conference 2015 - 41st European Solid-State Circuits Conference (ESSCIRC)\",\"volume\":\"13 1\",\"pages\":\"372-375\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-11-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ESSCIRC Conference 2015 - 41st European Solid-State Circuits Conference (ESSCIRC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESSCIRC.2015.7313905\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ESSCIRC Conference 2015 - 41st European Solid-State Circuits Conference (ESSCIRC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESSCIRC.2015.7313905","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A 13.2b optical proximity sensor system with 130klx ambient light rejection capable of heart rate and blood oximetry monitoring
A system for measuring optical proximity based on reflection of modulated light is presented. Its novel input stage topology comprising an AC coupled TIA and a two stage DC rejection circuit based on a synthesized inductive impedance, provides readouts with a resolution better than 13.2 ENOB. This allows the sensor system to be used without modifications also for heart rate and blood oximetry monitoring.