{"title":"新设计的与传统的用于早产儿心电记录带的比较","authors":"","doi":"10.35755/jmedassocthai.2023.05.13850","DOIUrl":null,"url":null,"abstract":"Objective: 1) To compare the outcomes of fetal heart rate monitoring using a newly-designed elastic cardiotocograph (CTG) bandage and a conventional ultrasound transducer bandage, and 2) to evaluate the satisfaction of the participants and labor staff using the newly-designed elastic CTG bandage compared to those using the conventional ultrasound transducer bandage.\n\nMaterials and Methods: The researchers invented the newly-designed elastic CTG bandage and conducted a quasi-experimental study with thirty-four pregnant women gestational age under 37 weeks using both the newly-designed elastic CTG bandage and the conventional ultrasound transducers. A comparison of the outcomes of fetal heart rate monitoring between the two methods was done using Wilcoxon signed-rank test. Then, two instruments (the CTG band satisfaction questionnaire for women, and the CTG band satisfaction questionnaire and fetal heart rate graph absence record for the labor staff) were administered to the respective participants. They were adapted for the study based on the diffusion of innovation model, which postulated that an innovation was generally adopted when five main factors (compatibility, complexity, trial-ability, observability, and relative advantage) were met.\n\nResults: The median score of signals of fetal heart rate loss when solely using the newly-designed elastic CTG bandage was only 1.0 times and the conventional ultrasound transducer bandage was 3.0 times. There was a significant difference (p<0.001). Most members of the labor staff were satisfied with the suitability of the newly-designed elastic CTG bandage.\n\nConclusion: The newly-designed elastic CTG bandage improved the quality of fetal heart rate assessment compared to the conventional ultrasound transducer bandage, resulting in the reduction of errors during examinations and the labor staff’s workloads while providing the ability to continuously assess the fetal heart rate.\n\nKeywords: Cardiotocograph; Fetal heart rate; Intrapartum fetal monitoring","PeriodicalId":17486,"journal":{"name":"Journal of the Medical Association of Thailand = Chotmaihet thangphaet","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison of a Newly-Designed and Conventional Strap Used for Cardiotocograph Recoding in Preterm Labor\",\"authors\":\"\",\"doi\":\"10.35755/jmedassocthai.2023.05.13850\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: 1) To compare the outcomes of fetal heart rate monitoring using a newly-designed elastic cardiotocograph (CTG) bandage and a conventional ultrasound transducer bandage, and 2) to evaluate the satisfaction of the participants and labor staff using the newly-designed elastic CTG bandage compared to those using the conventional ultrasound transducer bandage.\\n\\nMaterials and Methods: The researchers invented the newly-designed elastic CTG bandage and conducted a quasi-experimental study with thirty-four pregnant women gestational age under 37 weeks using both the newly-designed elastic CTG bandage and the conventional ultrasound transducers. A comparison of the outcomes of fetal heart rate monitoring between the two methods was done using Wilcoxon signed-rank test. Then, two instruments (the CTG band satisfaction questionnaire for women, and the CTG band satisfaction questionnaire and fetal heart rate graph absence record for the labor staff) were administered to the respective participants. They were adapted for the study based on the diffusion of innovation model, which postulated that an innovation was generally adopted when five main factors (compatibility, complexity, trial-ability, observability, and relative advantage) were met.\\n\\nResults: The median score of signals of fetal heart rate loss when solely using the newly-designed elastic CTG bandage was only 1.0 times and the conventional ultrasound transducer bandage was 3.0 times. There was a significant difference (p<0.001). Most members of the labor staff were satisfied with the suitability of the newly-designed elastic CTG bandage.\\n\\nConclusion: The newly-designed elastic CTG bandage improved the quality of fetal heart rate assessment compared to the conventional ultrasound transducer bandage, resulting in the reduction of errors during examinations and the labor staff’s workloads while providing the ability to continuously assess the fetal heart rate.\\n\\nKeywords: Cardiotocograph; Fetal heart rate; Intrapartum fetal monitoring\",\"PeriodicalId\":17486,\"journal\":{\"name\":\"Journal of the Medical Association of Thailand = Chotmaihet thangphaet\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Medical Association of Thailand = Chotmaihet thangphaet\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35755/jmedassocthai.2023.05.13850\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Medical Association of Thailand = Chotmaihet thangphaet","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35755/jmedassocthai.2023.05.13850","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:1)比较新设计的弹性心动图(CTG)绷带与传统超声换能器绷带监测胎儿心率的效果;2)评价新设计的弹性心动图绷带与传统超声换能器绷带对产妇和产程人员的满意度。材料与方法:研究人员发明了新设计的弹性CTG绷带,并对34名胎龄在37周以下的孕妇使用新设计的弹性CTG绷带和常规超声换能器进行了准实验研究。采用Wilcoxon符号秩检验比较两种方法的胎心率监测结果。然后分别发放两份工具(女性CTG带满意度问卷和产房工作人员CTG带满意度问卷和胎心图缺席记录表)。在创新扩散模型的基础上,假设一项创新通常在满足五个主要因素(兼容性、复杂性、可试验性、可观察性和相对优势)的情况下被采用。结果:单独使用新设计的弹性CTG绷带时,胎儿心率丢失信号的中位数评分仅为1.0次,而常规超声换能绷带的中位数评分为3.0次。差异有统计学意义(p<0.001)。大多数劳动人员对新设计的弹性CTG绷带的适用性感到满意。结论:与传统超声换能器绷带相比,新设计的弹性CTG绷带提高了胎儿心率评估的质量,减少了检查中的错误,减少了分娩人员的工作量,同时提供了持续评估胎儿心率的能力。关键词:分娩监护仪;胎儿心率;产时胎儿监护
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison of a Newly-Designed and Conventional Strap Used for Cardiotocograph Recoding in Preterm Labor
Objective: 1) To compare the outcomes of fetal heart rate monitoring using a newly-designed elastic cardiotocograph (CTG) bandage and a conventional ultrasound transducer bandage, and 2) to evaluate the satisfaction of the participants and labor staff using the newly-designed elastic CTG bandage compared to those using the conventional ultrasound transducer bandage. Materials and Methods: The researchers invented the newly-designed elastic CTG bandage and conducted a quasi-experimental study with thirty-four pregnant women gestational age under 37 weeks using both the newly-designed elastic CTG bandage and the conventional ultrasound transducers. A comparison of the outcomes of fetal heart rate monitoring between the two methods was done using Wilcoxon signed-rank test. Then, two instruments (the CTG band satisfaction questionnaire for women, and the CTG band satisfaction questionnaire and fetal heart rate graph absence record for the labor staff) were administered to the respective participants. They were adapted for the study based on the diffusion of innovation model, which postulated that an innovation was generally adopted when five main factors (compatibility, complexity, trial-ability, observability, and relative advantage) were met. Results: The median score of signals of fetal heart rate loss when solely using the newly-designed elastic CTG bandage was only 1.0 times and the conventional ultrasound transducer bandage was 3.0 times. There was a significant difference (p<0.001). Most members of the labor staff were satisfied with the suitability of the newly-designed elastic CTG bandage. Conclusion: The newly-designed elastic CTG bandage improved the quality of fetal heart rate assessment compared to the conventional ultrasound transducer bandage, resulting in the reduction of errors during examinations and the labor staff’s workloads while providing the ability to continuously assess the fetal heart rate. Keywords: Cardiotocograph; Fetal heart rate; Intrapartum fetal monitoring
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信