{"title":"x射线计算机断层扫描(XCT)扫描参数对AA2011 Hounsfield单元(HU)测量的影响","authors":"A. Baydoun, R. Hamade","doi":"10.1115/imece2021-67415","DOIUrl":null,"url":null,"abstract":"\n X-ray computed tomography (XCT) is a powerful technique that can detect internal defects and differentiate between different materials making XCT a valuable non-destructive evaluation (NDE). However, when X-ray CT is employed as an NDE method, the scanning parameters and methodology are often underreported leading to a lack of consensus on the optimal scanning parameters to use when analyzing a particular metal or alloy.\n In this study, 16-bit X-ray CT scans are employed to characterize AA2011. Four parameters are investigated: scan (voxel) resolution, tube voltage, tube current, and sample size (thickness). Two sample disks are scanned simultaneously at an image bit depth of 16-bit. Mean and standard deviation Hounsfield Unit (HU) values are calculated which are then used to develop a predictive model for these two values. The model equation is used to produce surface plots to determine desired scanning parameters combination for characterizing AA2011 HU mean and standard deviation values. It is concluded that higher scanning resolution (smaller voxel), larger tube voltage and tube current settings, and thicker samples result in smaller of standard deviation HU values and converged mean HU values when scanning AA2011.","PeriodicalId":23837,"journal":{"name":"Volume 3: Advanced Materials: Design, Processing, Characterization, and Applications","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"X-Ray Computed Tomography (XCT) Scanning Parameters Effects on the Hounsfield Unit (HU) Measurements for AA2011\",\"authors\":\"A. Baydoun, R. Hamade\",\"doi\":\"10.1115/imece2021-67415\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n X-ray computed tomography (XCT) is a powerful technique that can detect internal defects and differentiate between different materials making XCT a valuable non-destructive evaluation (NDE). However, when X-ray CT is employed as an NDE method, the scanning parameters and methodology are often underreported leading to a lack of consensus on the optimal scanning parameters to use when analyzing a particular metal or alloy.\\n In this study, 16-bit X-ray CT scans are employed to characterize AA2011. Four parameters are investigated: scan (voxel) resolution, tube voltage, tube current, and sample size (thickness). Two sample disks are scanned simultaneously at an image bit depth of 16-bit. Mean and standard deviation Hounsfield Unit (HU) values are calculated which are then used to develop a predictive model for these two values. The model equation is used to produce surface plots to determine desired scanning parameters combination for characterizing AA2011 HU mean and standard deviation values. It is concluded that higher scanning resolution (smaller voxel), larger tube voltage and tube current settings, and thicker samples result in smaller of standard deviation HU values and converged mean HU values when scanning AA2011.\",\"PeriodicalId\":23837,\"journal\":{\"name\":\"Volume 3: Advanced Materials: Design, Processing, Characterization, and Applications\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 3: Advanced Materials: Design, Processing, Characterization, and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/imece2021-67415\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3: Advanced Materials: Design, Processing, Characterization, and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2021-67415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

x射线计算机断层扫描(XCT)是一种强大的技术,可以检测内部缺陷和区分不同的材料,使XCT成为一种有价值的无损评估(NDE)。然而,当x射线CT被用作无损检测方法时,扫描参数和方法往往被低估,导致在分析特定金属或合金时对使用的最佳扫描参数缺乏共识。在本研究中,采用16位x线CT扫描来表征AA2011。研究了四个参数:扫描(体素)分辨率,管电压,管电流和样品尺寸(厚度)。以16位的图像位深度同时扫描两个样本磁盘。计算平均值和标准偏差霍斯菲尔德单位(HU)值,然后用于开发这两个值的预测模型。利用模型方程生成曲面图,确定表征AA2011 HU均值和标准差值所需的扫描参数组合。结果表明,扫描AA2011时,扫描分辨率越高(体素越小)、管电压和管电流设置越大、样品越厚,其标准差HU值和收敛均值HU值越小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
X-Ray Computed Tomography (XCT) Scanning Parameters Effects on the Hounsfield Unit (HU) Measurements for AA2011
X-ray computed tomography (XCT) is a powerful technique that can detect internal defects and differentiate between different materials making XCT a valuable non-destructive evaluation (NDE). However, when X-ray CT is employed as an NDE method, the scanning parameters and methodology are often underreported leading to a lack of consensus on the optimal scanning parameters to use when analyzing a particular metal or alloy. In this study, 16-bit X-ray CT scans are employed to characterize AA2011. Four parameters are investigated: scan (voxel) resolution, tube voltage, tube current, and sample size (thickness). Two sample disks are scanned simultaneously at an image bit depth of 16-bit. Mean and standard deviation Hounsfield Unit (HU) values are calculated which are then used to develop a predictive model for these two values. The model equation is used to produce surface plots to determine desired scanning parameters combination for characterizing AA2011 HU mean and standard deviation values. It is concluded that higher scanning resolution (smaller voxel), larger tube voltage and tube current settings, and thicker samples result in smaller of standard deviation HU values and converged mean HU values when scanning AA2011.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信