Wang Jun, Xu Xiaoyuan, Wen Yi-Zhi, Yu Changxuan, Wan Baonian, N. Luhmann, Wang Jian, Xia Zhengang
{"title":"HT-7托卡马克的一维垂直ECEI诊断","authors":"Wang Jun, Xu Xiaoyuan, Wen Yi-Zhi, Yu Changxuan, Wan Baonian, N. Luhmann, Wang Jian, Xia Zhengang","doi":"10.1088/1009-0630/8/1/17","DOIUrl":null,"url":null,"abstract":"At the first stage of the electron cyclotron emission imaging (ECEI) diagnostic project on HT-7, a 16-channel vertical-resolved ECEI diagnostic has been developed and installed on HT-7 tokamak to measure electron cyclotron emission with a temporal resolution of 0.5 μsec. The system works at a fixed frequency of 97.5 GHz. The sample volumes of the system are aligned vertically with a vertical channel spacing of 11 mm, and can be shifted across the plasma cross-section by varying the toroidal magnetic field. The high spatial resolution of the system is achieved by utilizing a low-cost linear mixer/receiver array and an optical imaging system. The focus location may be shifted horizontally when translating one of the optical imaging elements. The details of the system design and laboratory testing of the ECEI optics are presented together with the preliminary experimental results.","PeriodicalId":20250,"journal":{"name":"Plasma Science & Technology","volume":"213 1","pages":"76-79"},"PeriodicalIF":1.6000,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"One-Dimensional Vertical ECEI Diagnostic for HT-7 Tokamak\",\"authors\":\"Wang Jun, Xu Xiaoyuan, Wen Yi-Zhi, Yu Changxuan, Wan Baonian, N. Luhmann, Wang Jian, Xia Zhengang\",\"doi\":\"10.1088/1009-0630/8/1/17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"At the first stage of the electron cyclotron emission imaging (ECEI) diagnostic project on HT-7, a 16-channel vertical-resolved ECEI diagnostic has been developed and installed on HT-7 tokamak to measure electron cyclotron emission with a temporal resolution of 0.5 μsec. The system works at a fixed frequency of 97.5 GHz. The sample volumes of the system are aligned vertically with a vertical channel spacing of 11 mm, and can be shifted across the plasma cross-section by varying the toroidal magnetic field. The high spatial resolution of the system is achieved by utilizing a low-cost linear mixer/receiver array and an optical imaging system. The focus location may be shifted horizontally when translating one of the optical imaging elements. The details of the system design and laboratory testing of the ECEI optics are presented together with the preliminary experimental results.\",\"PeriodicalId\":20250,\"journal\":{\"name\":\"Plasma Science & Technology\",\"volume\":\"213 1\",\"pages\":\"76-79\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2006-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Plasma Science & Technology\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1088/1009-0630/8/1/17\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PHYSICS, FLUIDS & PLASMAS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasma Science & Technology","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1088/1009-0630/8/1/17","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHYSICS, FLUIDS & PLASMAS","Score":null,"Total":0}
One-Dimensional Vertical ECEI Diagnostic for HT-7 Tokamak
At the first stage of the electron cyclotron emission imaging (ECEI) diagnostic project on HT-7, a 16-channel vertical-resolved ECEI diagnostic has been developed and installed on HT-7 tokamak to measure electron cyclotron emission with a temporal resolution of 0.5 μsec. The system works at a fixed frequency of 97.5 GHz. The sample volumes of the system are aligned vertically with a vertical channel spacing of 11 mm, and can be shifted across the plasma cross-section by varying the toroidal magnetic field. The high spatial resolution of the system is achieved by utilizing a low-cost linear mixer/receiver array and an optical imaging system. The focus location may be shifted horizontally when translating one of the optical imaging elements. The details of the system design and laboratory testing of the ECEI optics are presented together with the preliminary experimental results.
期刊介绍:
PST assists in advancing plasma science and technology by reporting important, novel, helpful and thought-provoking progress in this strongly multidisciplinary and interdisciplinary field, in a timely manner.
A Publication of the Institute of Plasma Physics, Chinese Academy of Sciences and the Chinese Society of Theoretical and Applied Mechanics.