{"title":"使用具有超疏水表面的浓缩装置分析实际样品中的重金属离子","authors":"I. Yanagimachi, N. Nashida, K. Iwasa, H. Suzuki","doi":"10.1109/SENSOR.2007.4300411","DOIUrl":null,"url":null,"abstract":"Heavy metal ions in soil samples were analyzed by a novel method based on evaporative concentration. The detector chip had a microelectrode array as a working electrode and a Ag/AgCl reference electrode surrounded by a super-hydrophobic layer formed with polytetrafluoroethylene (PTFE) beads. A sample droplet formed on the electrode area was shrunk to concentrate the solution. Cd2+ , Pb2+ , and As3+ ions were analyzed by square wave anodic stripping voltammetry. By combining a protective layer and wet sample digestion, the heavy metal ions in soil samples could be analyzed. Correlation coefficients between the values obtained by this method and those by a conventional method was 0.982 (Pb2+), 0.969 (Cd2+), and 0.936 (As3+).","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"19 1","pages":"1425-1428"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Heavy Metal Ions in Real Samples using a Concentrator Device with a Super-Hydrophobic Surface\",\"authors\":\"I. Yanagimachi, N. Nashida, K. Iwasa, H. Suzuki\",\"doi\":\"10.1109/SENSOR.2007.4300411\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Heavy metal ions in soil samples were analyzed by a novel method based on evaporative concentration. The detector chip had a microelectrode array as a working electrode and a Ag/AgCl reference electrode surrounded by a super-hydrophobic layer formed with polytetrafluoroethylene (PTFE) beads. A sample droplet formed on the electrode area was shrunk to concentrate the solution. Cd2+ , Pb2+ , and As3+ ions were analyzed by square wave anodic stripping voltammetry. By combining a protective layer and wet sample digestion, the heavy metal ions in soil samples could be analyzed. Correlation coefficients between the values obtained by this method and those by a conventional method was 0.982 (Pb2+), 0.969 (Cd2+), and 0.936 (As3+).\",\"PeriodicalId\":23295,\"journal\":{\"name\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"volume\":\"19 1\",\"pages\":\"1425-1428\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2007.4300411\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2007.4300411","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Analysis of Heavy Metal Ions in Real Samples using a Concentrator Device with a Super-Hydrophobic Surface
Heavy metal ions in soil samples were analyzed by a novel method based on evaporative concentration. The detector chip had a microelectrode array as a working electrode and a Ag/AgCl reference electrode surrounded by a super-hydrophobic layer formed with polytetrafluoroethylene (PTFE) beads. A sample droplet formed on the electrode area was shrunk to concentrate the solution. Cd2+ , Pb2+ , and As3+ ions were analyzed by square wave anodic stripping voltammetry. By combining a protective layer and wet sample digestion, the heavy metal ions in soil samples could be analyzed. Correlation coefficients between the values obtained by this method and those by a conventional method was 0.982 (Pb2+), 0.969 (Cd2+), and 0.936 (As3+).