{"title":"反相高效液相色谱法测定甲磺酸沙非胺原料药和制剂含量的建立与验证","authors":"A. Rehman, Pasupathi Nath Tiwari, Sreenivasa Rao","doi":"10.52711/2231-5675.2022.00029","DOIUrl":null,"url":null,"abstract":"A rapid and highly sensitive high performance liquid chromatographic method has been developed for the determination of Safinamide Mesylate in bulk and in tablet dosage form. Safinamide mesylate was eluted from a XBridge C18 (250mmX4.6mm) reversed phase column with a mobile phase of Ammonium acetate buffer pH 5.8 and Acetonitrile in the ratio of 55:45 (v/v) at a flow rate of 1ml/min with UV detection of 26nm. The retention time for Safinamide mesylate was 3.8min. The linear response (r2 = 0.997) was observed in the range of 10-60 µg/ml with limits of detection (LOD) and quantification (LOQ) being 2.85 and 9.5µg/ml respectively. The method shows good recoveries and intra and inter-day relative standard deviations were less than 2%. Validation parameters as Specificity, accuracy, ruggedness and robustness were also determined. The proposed method provides accurate and precise quality control tool for routine of Safinamide mesylate in bulk and in tablet dosage form.","PeriodicalId":8547,"journal":{"name":"Asian Journal of Pharmaceutical Analysis","volume":"147 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and Validation of an RP-HPLC Method for the determination of Safinamide Mesylate in Bulk and Pharmaceutical Dosage Form\",\"authors\":\"A. Rehman, Pasupathi Nath Tiwari, Sreenivasa Rao\",\"doi\":\"10.52711/2231-5675.2022.00029\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A rapid and highly sensitive high performance liquid chromatographic method has been developed for the determination of Safinamide Mesylate in bulk and in tablet dosage form. Safinamide mesylate was eluted from a XBridge C18 (250mmX4.6mm) reversed phase column with a mobile phase of Ammonium acetate buffer pH 5.8 and Acetonitrile in the ratio of 55:45 (v/v) at a flow rate of 1ml/min with UV detection of 26nm. The retention time for Safinamide mesylate was 3.8min. The linear response (r2 = 0.997) was observed in the range of 10-60 µg/ml with limits of detection (LOD) and quantification (LOQ) being 2.85 and 9.5µg/ml respectively. The method shows good recoveries and intra and inter-day relative standard deviations were less than 2%. Validation parameters as Specificity, accuracy, ruggedness and robustness were also determined. The proposed method provides accurate and precise quality control tool for routine of Safinamide mesylate in bulk and in tablet dosage form.\",\"PeriodicalId\":8547,\"journal\":{\"name\":\"Asian Journal of Pharmaceutical Analysis\",\"volume\":\"147 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Pharmaceutical Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52711/2231-5675.2022.00029\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Pharmaceutical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52711/2231-5675.2022.00029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development and Validation of an RP-HPLC Method for the determination of Safinamide Mesylate in Bulk and Pharmaceutical Dosage Form
A rapid and highly sensitive high performance liquid chromatographic method has been developed for the determination of Safinamide Mesylate in bulk and in tablet dosage form. Safinamide mesylate was eluted from a XBridge C18 (250mmX4.6mm) reversed phase column with a mobile phase of Ammonium acetate buffer pH 5.8 and Acetonitrile in the ratio of 55:45 (v/v) at a flow rate of 1ml/min with UV detection of 26nm. The retention time for Safinamide mesylate was 3.8min. The linear response (r2 = 0.997) was observed in the range of 10-60 µg/ml with limits of detection (LOD) and quantification (LOQ) being 2.85 and 9.5µg/ml respectively. The method shows good recoveries and intra and inter-day relative standard deviations were less than 2%. Validation parameters as Specificity, accuracy, ruggedness and robustness were also determined. The proposed method provides accurate and precise quality control tool for routine of Safinamide mesylate in bulk and in tablet dosage form.