Stefan Mross, Peter Furst, S. Pierrat, T. Zimmermann, M. Kraft
{"title":"具有多层膜的CMOS恒电位器和传感器,用于葡萄糖浓度的大范围测量","authors":"Stefan Mross, Peter Furst, S. Pierrat, T. Zimmermann, M. Kraft","doi":"10.1109/ICSENS.2014.6985196","DOIUrl":null,"url":null,"abstract":"We report on an electrochemical measurement setup comprising a CMOS potentiostat and a glucose sensor with a two-layer membrane as the first steps towards the development of an integrated in-situ sensor system for bioreactors. The potentiostat has a chip size of 2.1 × 2.5 mm2 and a linear current range from -220 nA to 240 nA with a linearity of R2 = 0.9995. For wide range measurements of glucose concentrations in cell culture media, electrodes functionalized with the enzyme glucose oxidase were spin-coated with membranes made from polydimethylsiloxane (PDMS). With these membranes, glucose concentrations up to 400 mM were measured with a linear measurement range up to 100 mM. For interferent elimination, cellulose acetate membranes were employed.","PeriodicalId":13244,"journal":{"name":"IEEE SENSORS 2014 Proceedings","volume":"2 1","pages":"1096-1099"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"CMOS potentiostat and sensor with multilayer membrane for wide range measurements of glucose concentrations\",\"authors\":\"Stefan Mross, Peter Furst, S. Pierrat, T. Zimmermann, M. Kraft\",\"doi\":\"10.1109/ICSENS.2014.6985196\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report on an electrochemical measurement setup comprising a CMOS potentiostat and a glucose sensor with a two-layer membrane as the first steps towards the development of an integrated in-situ sensor system for bioreactors. The potentiostat has a chip size of 2.1 × 2.5 mm2 and a linear current range from -220 nA to 240 nA with a linearity of R2 = 0.9995. For wide range measurements of glucose concentrations in cell culture media, electrodes functionalized with the enzyme glucose oxidase were spin-coated with membranes made from polydimethylsiloxane (PDMS). With these membranes, glucose concentrations up to 400 mM were measured with a linear measurement range up to 100 mM. For interferent elimination, cellulose acetate membranes were employed.\",\"PeriodicalId\":13244,\"journal\":{\"name\":\"IEEE SENSORS 2014 Proceedings\",\"volume\":\"2 1\",\"pages\":\"1096-1099\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE SENSORS 2014 Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2014.6985196\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE SENSORS 2014 Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2014.6985196","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
CMOS potentiostat and sensor with multilayer membrane for wide range measurements of glucose concentrations
We report on an electrochemical measurement setup comprising a CMOS potentiostat and a glucose sensor with a two-layer membrane as the first steps towards the development of an integrated in-situ sensor system for bioreactors. The potentiostat has a chip size of 2.1 × 2.5 mm2 and a linear current range from -220 nA to 240 nA with a linearity of R2 = 0.9995. For wide range measurements of glucose concentrations in cell culture media, electrodes functionalized with the enzyme glucose oxidase were spin-coated with membranes made from polydimethylsiloxane (PDMS). With these membranes, glucose concentrations up to 400 mM were measured with a linear measurement range up to 100 mM. For interferent elimination, cellulose acetate membranes were employed.