挤压电缆绝缘中堵股材料的扩散

S. Pélissou, S. St.-Antoine, R. Savage
{"title":"挤压电缆绝缘中堵股材料的扩散","authors":"S. Pélissou, S. St.-Antoine, R. Savage","doi":"10.1109/ELINSL.2002.995979","DOIUrl":null,"url":null,"abstract":"This paper presents results on the impurity content of the insulation and shield of medium voltage extruded cables having a blocked strand material, before and after simulated field extreme thermal conditions. Cables are of the 15 and 28 kV class, with aluminum compact filled conductor, water tree retardant crosslinked polyethylene (WTRXLPE) insulated, extra-clean shields, and were made by three different cable manufacturers. Two cable conditioning were used: conductor inductive heating at 90/spl deg/C constant for more than 60 days, and then cycling up to 130/spl deg/C, 8 hours/ON and 16 hours/OFF, for 14 days. The impurity content measurements were performed by neutron activation analysis on ribbon samples peeled off the cables. The results indicate that the insulation and shields impurity contents are not much influenced by the presence of the block strand material in the cables after manufacturing and laboratory aging.","PeriodicalId":10532,"journal":{"name":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","volume":"7 1","pages":"481-484"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Diffusion of blocked strand material in the insulation of extruded cables\",\"authors\":\"S. Pélissou, S. St.-Antoine, R. Savage\",\"doi\":\"10.1109/ELINSL.2002.995979\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents results on the impurity content of the insulation and shield of medium voltage extruded cables having a blocked strand material, before and after simulated field extreme thermal conditions. Cables are of the 15 and 28 kV class, with aluminum compact filled conductor, water tree retardant crosslinked polyethylene (WTRXLPE) insulated, extra-clean shields, and were made by three different cable manufacturers. Two cable conditioning were used: conductor inductive heating at 90/spl deg/C constant for more than 60 days, and then cycling up to 130/spl deg/C, 8 hours/ON and 16 hours/OFF, for 14 days. The impurity content measurements were performed by neutron activation analysis on ribbon samples peeled off the cables. The results indicate that the insulation and shields impurity contents are not much influenced by the presence of the block strand material in the cables after manufacturing and laboratory aging.\",\"PeriodicalId\":10532,\"journal\":{\"name\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"volume\":\"7 1\",\"pages\":\"481-484\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2002.995979\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2002.995979","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文给出了在模拟现场极端热条件下,采用阻塞股材料的中压挤压电缆绝缘和屏蔽层杂质含量的计算结果。电缆是15和28千伏等级,铝紧凑填充导体,水树阻燃交联聚乙烯(WTRXLPE)绝缘,超清洁屏蔽,由三家不同的电缆制造商制造。采用两种电缆调理方式:导体在90/spl℃恒定感应加热60天以上,然后循环至130/spl℃,8小时/开,16小时/关,持续14天。通过中子活化分析对电缆上剥离的带状试样进行杂质含量测定。结果表明,在制造和实验室老化过程中,电缆中块股材料的存在对电缆的绝缘和屏蔽杂质含量影响不大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diffusion of blocked strand material in the insulation of extruded cables
This paper presents results on the impurity content of the insulation and shield of medium voltage extruded cables having a blocked strand material, before and after simulated field extreme thermal conditions. Cables are of the 15 and 28 kV class, with aluminum compact filled conductor, water tree retardant crosslinked polyethylene (WTRXLPE) insulated, extra-clean shields, and were made by three different cable manufacturers. Two cable conditioning were used: conductor inductive heating at 90/spl deg/C constant for more than 60 days, and then cycling up to 130/spl deg/C, 8 hours/ON and 16 hours/OFF, for 14 days. The impurity content measurements were performed by neutron activation analysis on ribbon samples peeled off the cables. The results indicate that the insulation and shields impurity contents are not much influenced by the presence of the block strand material in the cables after manufacturing and laboratory aging.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信