不同电缆长度、温度和试验电压下地下电缆极化和去极化电流的测量

K. Thungsook, P. Nimsanong, N. Marukatut, N. Pattanadech
{"title":"不同电缆长度、温度和试验电压下地下电缆极化和去极化电流的测量","authors":"K. Thungsook, P. Nimsanong, N. Marukatut, N. Pattanadech","doi":"10.1109/CMD.2018.8535789","DOIUrl":null,"url":null,"abstract":"This paper represents the polarization and depolarization current (PDC) measurement of 12/20(24) kV XLPE power cable with different cable lengths, cable dimensions, temperatures and test voltages. In experiment 1, the XLPE cable with 5 m long and cross section of 240 mm2 was prepared for (Case V1) investigation. Moreover, two of 2.5 m cables connected by the pre-molded joint (Case V2) was also prepared. In the experiment 1, the PDC experiment was investigated with different step DC test voltages i.e., 500V, 750V and 1,000V respectively. Besides, the dielectric response of underground cables with the length of 15 cm with cross section of 185 mm2 and the lengths of 2.5 m and 5 m with cross section of 240 mm2 including the length of 100 m with cross section of 70 mm2 were prepared for experiment 2. To investigate the effect of temperatures on dielectric response, the cable specimen with the length of 15 cm with cross section of 185 mm2 was set up under ambient temperatures of 30, 50, 70 and 90 degree Celsius for PDC measurement in experiment 3. PDC test results obtained from the experiments were compared. Then the dielectric parameters for PDC experiment such as charge difference analysis, capacitance ratio analysis, and polarization loss factor were analyzed and reported in this paper.","PeriodicalId":6529,"journal":{"name":"2018 Condition Monitoring and Diagnosis (CMD)","volume":"13 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Polarization and Depolarization Current Measurement of Underground Cable with Different Cable lengths, Temperatures and Test Voltages\",\"authors\":\"K. Thungsook, P. Nimsanong, N. Marukatut, N. Pattanadech\",\"doi\":\"10.1109/CMD.2018.8535789\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper represents the polarization and depolarization current (PDC) measurement of 12/20(24) kV XLPE power cable with different cable lengths, cable dimensions, temperatures and test voltages. In experiment 1, the XLPE cable with 5 m long and cross section of 240 mm2 was prepared for (Case V1) investigation. Moreover, two of 2.5 m cables connected by the pre-molded joint (Case V2) was also prepared. In the experiment 1, the PDC experiment was investigated with different step DC test voltages i.e., 500V, 750V and 1,000V respectively. Besides, the dielectric response of underground cables with the length of 15 cm with cross section of 185 mm2 and the lengths of 2.5 m and 5 m with cross section of 240 mm2 including the length of 100 m with cross section of 70 mm2 were prepared for experiment 2. To investigate the effect of temperatures on dielectric response, the cable specimen with the length of 15 cm with cross section of 185 mm2 was set up under ambient temperatures of 30, 50, 70 and 90 degree Celsius for PDC measurement in experiment 3. PDC test results obtained from the experiments were compared. Then the dielectric parameters for PDC experiment such as charge difference analysis, capacitance ratio analysis, and polarization loss factor were analyzed and reported in this paper.\",\"PeriodicalId\":6529,\"journal\":{\"name\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"volume\":\"13 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CMD.2018.8535789\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Condition Monitoring and Diagnosis (CMD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CMD.2018.8535789","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

介绍了12/20(24)kV交联聚乙烯电力电缆在不同电缆长度、电缆尺寸、温度和试验电压条件下的极化和去极化电流(PDC)测量。在实验1中,制备了长5 m,横截面240 mm2的XLPE电缆用于(病例V1)研究。此外,还准备了两根2.5 m电缆,通过预成型接头(Case V2)连接。实验1采用不同阶跃直流试验电压500V、750V和1000v对PDC试验进行了研究。此外,实验2还制备了长度为15cm、截面为185mm2、长度为2.5 m、5m、截面为240mm2的地下电缆,其中长度为100m、截面为70mm2的地下电缆的介电响应。为了研究温度对介电响应的影响,实验3分别在环境温度为30、50、70、90℃的条件下,设置了长度为15 cm、截面为185 mm2的电缆试样进行PDC测量。对实验得到的PDC试验结果进行了比较。在此基础上,对PDC实验的介电参数如电荷差分析、电容比分析、极化损耗因子等进行了分析和报道。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Polarization and Depolarization Current Measurement of Underground Cable with Different Cable lengths, Temperatures and Test Voltages
This paper represents the polarization and depolarization current (PDC) measurement of 12/20(24) kV XLPE power cable with different cable lengths, cable dimensions, temperatures and test voltages. In experiment 1, the XLPE cable with 5 m long and cross section of 240 mm2 was prepared for (Case V1) investigation. Moreover, two of 2.5 m cables connected by the pre-molded joint (Case V2) was also prepared. In the experiment 1, the PDC experiment was investigated with different step DC test voltages i.e., 500V, 750V and 1,000V respectively. Besides, the dielectric response of underground cables with the length of 15 cm with cross section of 185 mm2 and the lengths of 2.5 m and 5 m with cross section of 240 mm2 including the length of 100 m with cross section of 70 mm2 were prepared for experiment 2. To investigate the effect of temperatures on dielectric response, the cable specimen with the length of 15 cm with cross section of 185 mm2 was set up under ambient temperatures of 30, 50, 70 and 90 degree Celsius for PDC measurement in experiment 3. PDC test results obtained from the experiments were compared. Then the dielectric parameters for PDC experiment such as charge difference analysis, capacitance ratio analysis, and polarization loss factor were analyzed and reported in this paper.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信