在三级保健中心应用occlutech装置经导管闭合术治疗房间隔缺损的程序技术和疗效

PAFMJ Pub Date : 2021-12-31 DOI:10.51253/pafmj.v71i6.3342
Asma Kanwal, Abdul Malik Shiekh, Kiran Azim, Khushal Khan Khattak
{"title":"在三级保健中心应用occlutech装置经导管闭合术治疗房间隔缺损的程序技术和疗效","authors":"Asma Kanwal, Abdul Malik Shiekh, Kiran Azim, Khushal Khan Khattak","doi":"10.51253/pafmj.v71i6.3342","DOIUrl":null,"url":null,"abstract":"Objective: To determine the safety and efficacy of transcatheter closure of atrial septal defects and to evaluate the initial, midterm and long-term results of the treatment. \nStudy Design: Cross sectional study. \nPlace and Duration of Study: Department of Paediatric Cardiology, Rawalpindi Institute of Cardiology, Rawalpindi, from Jul 2017 to Jun 2018. \nMethodology: Sixty-four patients underwent transcatheter closure of atrial septal defect. Size of the defect was measured by Transoesophageal/Transthoracic. Follow up was carried out at twenty-four hours, one month, six months and at twelve months. Early, Midterm and late complications after device occlusion were analysed using SPSS-22 statistical software. \nResults: Minimum size of atrial septal defect on echocardiography was 7 mm and maximum size was 31 mm with mean of 18.3 ± 5.7 mm. The procedure was successful in 96.8% cases. There was only one device embolization (1.56%). Cobrahead” configuration malformation of the device occurred in one case (1.56%). Mitral valve regurgitation did not occur in any of the case. There was no residual shunt across the device in the present study. ECG abnormalities associated with transcatheter closure did not occur in any of the patient. In intermediate and long-term follow up, no complication like cardiac erosion was seen in all cases under study. \nConclusion: Transcatheter occlusion of ASD with device was found effective and safe procedure with minimal complication rate, short hospital stay, good short, intermediate and long-term results.","PeriodicalId":19982,"journal":{"name":"PAFMJ","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"PROCEDURAL TECHNICALITIES AND OUTCOME OF TRANSCATHETER CLOSURE OF ATRIAL SEPTAL DEFECT USING OCCLUTECH DEVICE IN TERTIARY CARE CENTRE\",\"authors\":\"Asma Kanwal, Abdul Malik Shiekh, Kiran Azim, Khushal Khan Khattak\",\"doi\":\"10.51253/pafmj.v71i6.3342\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective: To determine the safety and efficacy of transcatheter closure of atrial septal defects and to evaluate the initial, midterm and long-term results of the treatment. \\nStudy Design: Cross sectional study. \\nPlace and Duration of Study: Department of Paediatric Cardiology, Rawalpindi Institute of Cardiology, Rawalpindi, from Jul 2017 to Jun 2018. \\nMethodology: Sixty-four patients underwent transcatheter closure of atrial septal defect. Size of the defect was measured by Transoesophageal/Transthoracic. Follow up was carried out at twenty-four hours, one month, six months and at twelve months. Early, Midterm and late complications after device occlusion were analysed using SPSS-22 statistical software. \\nResults: Minimum size of atrial septal defect on echocardiography was 7 mm and maximum size was 31 mm with mean of 18.3 ± 5.7 mm. The procedure was successful in 96.8% cases. There was only one device embolization (1.56%). Cobrahead” configuration malformation of the device occurred in one case (1.56%). Mitral valve regurgitation did not occur in any of the case. There was no residual shunt across the device in the present study. ECG abnormalities associated with transcatheter closure did not occur in any of the patient. In intermediate and long-term follow up, no complication like cardiac erosion was seen in all cases under study. \\nConclusion: Transcatheter occlusion of ASD with device was found effective and safe procedure with minimal complication rate, short hospital stay, good short, intermediate and long-term results.\",\"PeriodicalId\":19982,\"journal\":{\"name\":\"PAFMJ\",\"volume\":\"15 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"PAFMJ\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51253/pafmj.v71i6.3342\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"PAFMJ","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51253/pafmj.v71i6.3342","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨经导管闭合术治疗房间隔缺损的安全性和有效性,评价其初期、中期和远期疗效。研究设计:横断面研究。研究地点和时间:2017年7月至2018年6月,拉瓦尔品第心脏病研究所儿科心内科。方法:64例患者行房间隔缺损经导管闭合术。经食管/经胸测量缺损的大小。随访时间分别为24小时、1个月、6个月和12个月。采用SPSS-22统计软件对器械闭塞后早、中、晚期并发症进行分析。结果:超声心动图显示房间隔缺损最小尺寸为7 mm,最大尺寸为31 mm,平均为18.3±5.7 mm。手术成功率96.8%。器械栓塞1例(1.56%)。1例(1.56%)发生设备“Cobrahead”配置畸形。所有病例均未发生二尖瓣返流。在本研究中,没有残留的分流装置。与经导管闭合相关的心电图异常未在任何患者中发生。在中期和长期随访中,所有病例均未见心脏糜烂等并发症。结论:该装置经导管封堵ASD是一种安全有效的方法,并发症发生率低,住院时间短,短期、中期和长期效果良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PROCEDURAL TECHNICALITIES AND OUTCOME OF TRANSCATHETER CLOSURE OF ATRIAL SEPTAL DEFECT USING OCCLUTECH DEVICE IN TERTIARY CARE CENTRE
Objective: To determine the safety and efficacy of transcatheter closure of atrial septal defects and to evaluate the initial, midterm and long-term results of the treatment. Study Design: Cross sectional study. Place and Duration of Study: Department of Paediatric Cardiology, Rawalpindi Institute of Cardiology, Rawalpindi, from Jul 2017 to Jun 2018. Methodology: Sixty-four patients underwent transcatheter closure of atrial septal defect. Size of the defect was measured by Transoesophageal/Transthoracic. Follow up was carried out at twenty-four hours, one month, six months and at twelve months. Early, Midterm and late complications after device occlusion were analysed using SPSS-22 statistical software. Results: Minimum size of atrial septal defect on echocardiography was 7 mm and maximum size was 31 mm with mean of 18.3 ± 5.7 mm. The procedure was successful in 96.8% cases. There was only one device embolization (1.56%). Cobrahead” configuration malformation of the device occurred in one case (1.56%). Mitral valve regurgitation did not occur in any of the case. There was no residual shunt across the device in the present study. ECG abnormalities associated with transcatheter closure did not occur in any of the patient. In intermediate and long-term follow up, no complication like cardiac erosion was seen in all cases under study. Conclusion: Transcatheter occlusion of ASD with device was found effective and safe procedure with minimal complication rate, short hospital stay, good short, intermediate and long-term results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信