S. Patharkar, K. Gajbhiye, Nawaz Hakam, AM. Vyawahare
{"title":"片剂剂型中驱虫剂含量新分析方法的建立与验证","authors":"S. Patharkar, K. Gajbhiye, Nawaz Hakam, AM. Vyawahare","doi":"10.52711/2231-5675.2022.00018","DOIUrl":null,"url":null,"abstract":"A rapid, sensitive and accurate method for Estimation of Anti- Histamine in Tablet Dosage Form by RP-HPLC. Mobile phase was Methanol: 0.1% Ortho phosphoric acid (80:20% v/v). Flow rate was 0.9 ml/min. The detection Wavelength was 227 nm. The injection volume was 20-µl. The proposed method was validated for selectivity, precision, linearity, and accuracy. All validation parameters were within the acceptable range. Linearity studies for Levamisole was performed (10-60µg/ml). The %RSD for accuracy found to be less than2%. Assay was found to be 99.17 to 101.65 respectively The range of 10-60µg /ml was selected for the linearity of a standard Levamisole. The 80%, 100% and 120% levels of recovery study were selected to perform the recovery study. Linearity studies for Levamisole was performed on (10-60µg /ml).","PeriodicalId":8547,"journal":{"name":"Asian Journal of Pharmaceutical Analysis","volume":"32 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Development and Validation of New Analytical Method for Estimation of Anthelmintic in Tablet Dosage Form\",\"authors\":\"S. Patharkar, K. Gajbhiye, Nawaz Hakam, AM. Vyawahare\",\"doi\":\"10.52711/2231-5675.2022.00018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A rapid, sensitive and accurate method for Estimation of Anti- Histamine in Tablet Dosage Form by RP-HPLC. Mobile phase was Methanol: 0.1% Ortho phosphoric acid (80:20% v/v). Flow rate was 0.9 ml/min. The detection Wavelength was 227 nm. The injection volume was 20-µl. The proposed method was validated for selectivity, precision, linearity, and accuracy. All validation parameters were within the acceptable range. Linearity studies for Levamisole was performed (10-60µg/ml). The %RSD for accuracy found to be less than2%. Assay was found to be 99.17 to 101.65 respectively The range of 10-60µg /ml was selected for the linearity of a standard Levamisole. The 80%, 100% and 120% levels of recovery study were selected to perform the recovery study. Linearity studies for Levamisole was performed on (10-60µg /ml).\",\"PeriodicalId\":8547,\"journal\":{\"name\":\"Asian Journal of Pharmaceutical Analysis\",\"volume\":\"32 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Pharmaceutical Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52711/2231-5675.2022.00018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Pharmaceutical Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52711/2231-5675.2022.00018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development and Validation of New Analytical Method for Estimation of Anthelmintic in Tablet Dosage Form
A rapid, sensitive and accurate method for Estimation of Anti- Histamine in Tablet Dosage Form by RP-HPLC. Mobile phase was Methanol: 0.1% Ortho phosphoric acid (80:20% v/v). Flow rate was 0.9 ml/min. The detection Wavelength was 227 nm. The injection volume was 20-µl. The proposed method was validated for selectivity, precision, linearity, and accuracy. All validation parameters were within the acceptable range. Linearity studies for Levamisole was performed (10-60µg/ml). The %RSD for accuracy found to be less than2%. Assay was found to be 99.17 to 101.65 respectively The range of 10-60µg /ml was selected for the linearity of a standard Levamisole. The 80%, 100% and 120% levels of recovery study were selected to perform the recovery study. Linearity studies for Levamisole was performed on (10-60µg /ml).